Results 61 to 70 of about 1,373 (216)

Spectral Characteristics and Evolution Mechanism of Silicon Rubber Surface Discharge Under Thermal Ageing Condition

open access: yesHigh Voltage, Volume 11, Issue 1, Page 192-200, February 2026.
ABSTRACT Surface discharge is a typical fault type in electric power equipment. High temperature in long‐term operation can easily lead to ageing of materials, resulting in changes in surface characteristics and surface discharge faults. In this paper, a method of surface discharge identification of silicon rubber (SiR) based on spectral detection ...
Yanze Han   +6 more
wiley   +1 more source

Testing of Local Control Cabinet In Gas Insulated Switchgear Using Design of Simulation Kit - Revista

open access: yes, 2019
In order to keep generation and distribution of power at high priority, two switchgear playing a key role i) Air insulated Substation/Switchgear (AIS) ii) Gas Insulated Substation/Switchgear (GIS).
Holm-Nielsen, Jens Bo; id_orcid   +11 more
core   +1 more source

Breakdown Voltage Using Bond Energy Calculation for CF3CHCl2/CO2 Mixture as Insulation Applied

open access: yesJAREE (Journal on Advanced Research in Electrical Engineering), 2019
— Sulfur hexafluoride gas according to the Montreal Protocol and Kyoto protocol needs to be limited and gradually reduced because it causes global warming, the greenhouse effect and acid rain on the environment.
Tedy Juliandhy
doaj  

Adsorption properties of Ni cluster modified TiO2 (1 0 1) towards SF6 decomposition gases

open access: yesHigh Voltage, 2023
Online detection of insulation defects the decomposition products of SF6 plays a key role in ensuring the safe operation of the gas‐insulated switchgear (GIS) equipment. The pristine TiO2 (1 0 1) modified by Ni cluster (1–3 Ni atoms) is used as a new gas‐
Yingang Gui   +3 more
doaj   +1 more source

Nondestructive Measurement of Residual Stress on Epoxy Insulators Using Thermoelastic Method

open access: yesHigh Voltage, Volume 11, Issue 1, Page 274-283, February 2026.
ABSTRACT Residual stress is inevitable in epoxy insulators, which easily leads to small cracks and even insulation breakdown during the operation of gas‐insulated transmission line (GIL)/gas‐insulated switchgear (GIS). This study proposes a nondestructive method to measure the residual stress on epoxy insulators using thermoelastic effects.
Hucheng Liang, Bei Chu, Boxue Du
wiley   +1 more source

Quantitative Evaluation of Mechanical Defects for Circuit Breakers Based on Self‐Adaptive Fault Feature Tracking

open access: yesHigh Voltage, Volume 11, Issue 1, Page 297-304, February 2026.
ABSTRACT Many researchers are committed to improving the diagnosis accuracy and solving the few‐shot problem on circuit breakers (CBs). However, the research on the vibration transmission mechanism of the fault is insufficient, which makes it difficult to find the potential design defects of CBs through vibration.
Jiayi Gong   +3 more
wiley   +1 more source

Evaluasi kualitas gas SF6 pada Gas insulated Switchgear setelah revitalisasi studi kasus pada PT. PLN (PERSERO) GIS Simpang

open access: yes
Penelitian ini bertujuan mengevaluasi efektivitas revitalisasi pada Gas Insulated Switchgear (Gas Insulated Switchgear (GIS)) Simpang milik PT. PLN (Persero) dengan fokus pada kualitas gas SF6. Selain kemurnian, parameter lain seperti kadar air (moisture
Jamal, Mario
core   +3 more sources

Electric Field Improvement and Insulation Performance Enhancement of a Compact 40.5 kV Eco-Friendly Gas-Insulated Switchgear

open access: yesEnergies
With the ongoing trend of miniaturization and intelligent power transmission equipment, the compact design of environmentally friendly gas-insulated switchgear (GIS) has emerged as a critical technical challenge. This study presents a detailed case study
Dongyun Dai   +4 more
doaj   +1 more source

Surface Flashover in 50 Years: III. Extreme Environments and Industrial Challenges

open access: yesHigh Voltage, Volume 11, Issue 1, Page 100-142, February 2026.
ABSTRACT Modern high‐voltage electrical equipment operates in complex environments where surface conditions are subjected to multifaceted influences from electric fields, thermal gradients, contaminants, irradiation and other extreme environmental factors.
Zhen Li   +6 more
wiley   +1 more source

Digital Twin of an Electrical Insulation System: Data Communication, Predictive Models and Health Condition

open access: yesDigital Twins and Applications, Volume 3, Issue 1, January/December 2026.
Life and reliability models, potentially able to account for any type of stress, even time varying, are developed and their integration in a digital twin is discussed. Algorithms for the dynamic assessment of insulation health condition through diagnostic testing or monitoring, are developed.
Gian Carlo Montanari   +2 more
wiley   +1 more source