Results 41 to 50 of about 4,822,566 (311)
The conductor connection structure in gas-insulated transmission lines (GIL) is vital for power grid stability. Traditional inspections require power outages or fault signal detection post-failure, lacking real-time internal structure assessment.
Chao Li +8 more
semanticscholar +1 more source
The temperature distribution of the tri‐post insulator in a ±500 kV direct current gas‐insulated transmission lines (DC‐GIL) is investigated. The influence of thermal gradient on the electric field characteristics is investigated as well.
Xiaolong Li +4 more
doaj +1 more source
Characteristics investigation of R407C in high voltage applications as an alternative to SF6
The concept of life without electrical power is not possible. All the industrial, domestic zones etc., requires power to operate, which is transmitted by means of overhead high voltage transmission lines from generating stations to sub-stations.
Imad M. Khattak +7 more
doaj +1 more source
Testing and validating the electrical insulation performance of full-size compact high-voltage direct current (HVDC) gas-insulated systems, gas-insulated transmission lines (GIL) and gas-insulated switchgears (GIS) is very costly and take long time ...
Nabila Zebouchi +2 more
doaj +1 more source
The temperature properties of real-type direct-current gas-insulated transmission lines (DC-GIL) with a basin-type spacer were investigated by the finite element method in this paper.
Xiaolong Li +3 more
doaj +1 more source
Current Status and Challenges in Data Collection for Aerospace Coatings Deposited by Plasma Spraying
An innovative approach has been integrated into the GRENAT project to optimize plasma spraying and coating performance. Raw materials are accelerated and melted in the plasma generated by torches, creating coatings. Monitoring sensors collect process data which are combined with ex situ characterization data.
Lila Randriamananjara +8 more
wiley +1 more source
Eco-friendly alternatives to replace SF6 in high voltage Gas-Insulated Transmission Lines: a comparative study [PDF]
This project focuses on the research of an eco-friendly alternative that could replace SF_6, which is a strong greenhouse gas, in high voltage Gas-Insulated Transmission Lines, reducing the environmental impact but at the same time maintaining the ...
Manganella, Andrea
core
Wavelet-Based Adaptive Solution for the Nonuniform Multiconductor Transmission Lines [PDF]
—A time-domain technique for the solution of arbi-trary nonuniform multiconductor transmission lines (NMTL’s) is presented. The technique is based on a weak formulation of the NMTL equations obtained through spatial expansion of the voltage and current ...
S. Grivet-talocia +4 more
core +1 more source
Low‐voltage FIB‐SEM tomography combined with a image preprocessing pipeline improves phase contrast and enables reliable machine‐learning segmentation of conductive networks in lithium‐ion battery electrodes. Structural descriptors are extracted from segmented images, done semimanually and automated, and compared.
Lisa Beran +6 more
wiley +1 more source
FastNano Liquid: An Automated Platform for Small‐Angle X‐ray Scattering‐Based Materials Discovery
We present FastNano Liquid, an automated small‐ and wide‐angle X‐ray scattering platform for the combined synthesis and characterization of (nano)materials. The platform is coupled to varied reactor workflows for both in situ studies of reaction kinetics and ex situ screening of synthesis conditions to support machine learning‐guided exploration ...
Pierre‐Baptiste Flandrin +16 more
wiley +1 more source

