Results 1 to 10 of about 188 (86)

Retinal nerve fibre layer assessment in myopic glaucomatous eyes: comparison of GDx variable corneal compensation with GDx enhanced corneal compensation [PDF]

open access: yesBritish Journal of Ophthalmology, 2008
To compare the results of scanning laser polarimetry (GDx) with variable corneal compensation (VCC) and enhanced corneal compensation (ECC) when applied to myopic glaucomatous eyes.Forty glaucoma eyes with moderate myopia (between -3 and -6 D) and 35 glaucoma eyes with high myopia (-8 D or greater) were enrolled in this study.
Shigeo Morishita
exaly   +5 more sources

Impact of Atypical Retardation Patterns on Detection of Glaucoma Progression using the GDx with Variable Corneal Compensation [PDF]

open access: yesAmerican Journal of Ophthalmology, 2009
To evaluate the impact of atypical retardation patterns (ARP) on detection of progressive retinal nerve fiber layer (RNFL) loss using scanning laser polarimetry with variable corneal compensation (VCC).Observational cohort study.The study included 377 eyes of 221 patients with a median follow-up of 4.0 years.
Luciana M Alencar   +2 more
exaly   +5 more sources

The Impact of Retardance Pattern Variability on Nerve Fiber Layer Measurements over Time Using GDx with Variable and Enhanced Corneal Compensation [PDF]

open access: yesInvestigative Ophthalmology and Visual Science, 2011
To examine the impact of retardance pattern variability on retinal nerve fiber layer (RNFL) measurements over time using scanning laser polarimetry with variable (GDxVCC) and enhanced corneal compensation (GDxECC; both by Carl Zeiss Meditec, Inc., Dublin, CA).Glaucoma suspect and glaucomatous eyes with 4 years of follow-up participating in the Advanced
Richard J. Cook   +2 more
exaly   +5 more sources

Phase I NT-501 Ciliary Neurotrophic Factor Implant Trial for Primary Open-Angle Glaucoma [PDF]

open access: yesOphthalmology Science, 2023
Purpose: To assess the safety and efficacy of a ciliary neurotrophic factor (CNTF) intraocular implant on neuroprotection and neuroenhancement in glaucoma. Design: Open-label, prospective, phase I clinical trial.
Jeffrey L. Goldberg, MD, PhD   +5 more
doaj   +2 more sources

Effect of panretinal photocoagulation on the peripapillary retinal nerve fiber layer in diabetic retinopathy patients [PDF]

open access: yesClinics, 2019
OBJECTIVES: To determine the effect of panretinal photocoagulation (PRP) on the peripapillary retinal nerve fiber layer (RNFL) in nonglaucomatous patients with proliferative diabetic retinopathy (PDR).
Leandro Cabral Zacharias   +6 more
doaj   +3 more sources

Follow-up of the retinal nerve fiber layer thickness of diabetic patients type 2, as a predisposing factor for glaucoma compared to normal subjects [PDF]

open access: yesClinical Ophthalmology, 2017
Alexandros Takis,1 Dimitrios Alonistiotis,1 Nikolaos Ioannou,1 Evgenia Kontou,1 Maria Mitsopoulou,1 Dimitrios Papaconstantinou2 1Second Department of Ophthalmology, University of Athens, “Attikon” Hospital, Athens, 2First Department of ...
Takis A   +5 more
doaj   +2 more sources

Accuracy of GDx variable corneal compensation polarization measurements in normal human eyes: effect of accommodation, cycloplegia, focus, pupil size, and eye selection on reproducibility [PDF]

open access: yesEye, 2005
To evaluate the reproducibility of variable corneal compensation (VCC) and the effect of accommodation, cycloplegia, eye selection, focus, and pupil size on this measurement of polarization.Using a GDx scanning laser polarimeter, multiple measurements of the VCC were obtained from each eye of 33 healthy, young adults under differing conditions.
N S, Levy, I H, Schachar
exaly   +3 more sources

Assessment of peripapillary retinal nerve fiber layer thickness using scanning laser polarimetry (GDx VCC) in normal Indian children

open access: yesIndian Journal of Ophthalmology, 2013
Purpose: To obtain reference values of RNFL thickness in normal Indian children and to study the association of RNFL thickness with central corneal thickness(CCT) and axial length(AL). Materials and Methods: 200 normal Indian children (mean age 8.6 ± 2.9
Mayuri B Khamar   +4 more
doaj   +2 more sources

Effect of cataract surgery on retinal nerve fiber layer thickness parameters using scanning laser polarimetry (GDxVCC) [PDF]

open access: yesIndian Journal of Ophthalmology, 2010
Purpose: To study the effect of cataract extraction on the retinal nerve fiber layer (RNFL) thickness, and assessment by scanning laser polarimetry (SLP), with variable corneal compensation (GDx VCC), at the glaucoma service of a tertiary care center in ...
Dada Tanuj   +5 more
doaj   +2 more sources

Evaluating Glaucomatous Retinal Nerve Fiber Damage by GDx VCC Polarimetry in Taiwan Chinese Population

open access: yesJournal of Optometry, 2009
Purpose: To study the capability of scanning laser polarimetry with variable corneal compensation (GDx VCC) to detect differences in retinal nerve fiber layer thickness between normal and glaucomatous eyes in a Taiwan Chinese population.
Mei-Ling Huang
exaly   +3 more sources

Home - About - Disclaimer - Privacy