Results 121 to 130 of about 64,212 (257)
The Impact of Incorporating Shell-corrections to Energy Loss in Silicon
Modern silicon tracking detectors based on hybrid or fully integrated CMOS technology are continuing to push to thinner sensors. The ionization energy loss fluctuation in very thin silicon sensors significantly deviates from the Landau distribution ...
Dong, Su +4 more
core +1 more source
CaTS: Integration of Geant4 and Opticks [PDF]
CaTS [6]is an advanced example that is part of Geant4 since version 11.0. It demonstrates the use of Opticks to offload the simulation of optical photons to GPUs.
Wenzel Hans +3 more
doaj +1 more source
How to create an interface between UrQMD and Geant4 toolkit
An interface between the UrQMD-1.3cr model (version 1.3 for cosmic air showers) and the Geant4 transport toolkit has been developed. Compared to the current Geant4 (hybrid) hadronic models, this provides the ability to simulate at the microscopic level ...
Abdel-Waged, Khaled +2 more
core
Nuclear spectroscopy with Geant4 [PDF]
The simulation toolkit Geant4 was originally developed at CERN for high-energy physics. Over the years it has been established as a swiss army knife not only in particle physics but it has seen an accelerated expansion towards nuclear physics and more recently to medical imaging and y- and ion-therapy to mention but a handful of new applications.
openaire +1 more source
Given the sensitivity of proton therapy to anatomical variations, this cancer treatment modality is expected to benefit greatly from integration with magnetic resonance (MR) imaging.
Bussmann, Michael +5 more
core +1 more source
The Geant4 Virtual Monte Carlo
The Virtual Monte Carlo (VMC) [1] provides an abstract interface into the Monte Carlo transport codes: Geant3, Geant4 and Fluka. The user VMC based application, independent from the specific Monte Carlo codes, can then be run with all three simulation programs.
openaire +2 more sources
Geant4-DNA simulation of human cancer cells irradiation with helium ion beams.
K. Chatzipapas +14 more
semanticscholar +1 more source
Monte Carlo simulation-based dosimetric evaluation of a novel 125I brachytherapy source: Comparative assessment of dosimetry parameters and shadowing effects [PDF]
This study investigates a novel 125I radiotherapy source. It evaluates its dosimetric parameters using Monte Carlo simulation around the source, following the updated American Association of Physicists in Medicine Task Group recommendations. For
Duo Wan +3 more
doaj +1 more source
Geant4 validation with CMS calorimeters test-beam data
CMS experiment is using Geant4 for Monte-Carlo simulation of the detector setup. Validation of physics processes describing hadronic showers is a major concern in view of getting a proper description of jets and missing energy for signal and background ...
Piperov, Stefan
core
In a cyclotron-based proton therapy facility, the energy changes are performed by means of a degrader of variable thickness. The interaction of the proton beam with the degrader creates energy tails and increases the beam emittance.
Adelmann, A. +5 more
core +1 more source

