Results 121 to 130 of about 1,744 (162)

D-NA5.1 Smart Grid configuration validation scenario description method [PDF]

open access: yes, 2017
Abdulhadi , Ibrahim F.   +16 more
core  
Some of the next articles are maybe not open access.

Related searches:

International Electrotechnical Commission 61850 Routable Generic Object-Oriented Substation Event Messages: A Secure Data-Centric Communication Approach

IEEE Industry Applications Magazine, 2023
The necessity of critical communication between intelligent electronic devices (IEDs) in different substations led to expanding the Generic Object-Oriented Substation Event protocol (GOOSE) from the local area network (LAN) to the wide area network (WAN).
T. Youssef   +3 more
semanticscholar   +1 more source

Analyzing GOOSE Security in IEC61850-based Substation Using ML, SDN and Digital Twin

North American Power Symposium, 2023
This paper introduces a cyber digital twin (CDT) for supporting the analysis of power system substation network security and validating solutions utilizing Machine Learning (ML) and Software Defined Networking (SDN). This work focuses on targeted attacks
Peter K Yegorov   +5 more
semanticscholar   +1 more source

A System Configuration description Language (SCL) Complied File Based Configuration Method for Bridges in Smart Substation

International Conference Smart Grid and Smart Cities, 2023
Configuration of smart substation network which composed by bridges and IEDs (Intelligent Electronic Devices), always faces complicated pre-planning and commissioning work and involved with multiple vendors and various configuration file format.
Qin Li, Dehui Wang, Xin Huang, Hao Zhang
semanticscholar   +1 more source

Alerga: Alert Aggregation and Reasoning in GOOSE Simulation Pipeline

IEEE International Conference on Smart Grid Communications, 2023
IEC 61850 specifies the Generic Object Oriented Substation Event (GOOSE) protocol as one option for low latency communication of substation-related events.
Jude Battista   +3 more
semanticscholar   +1 more source

Communication bandwidth considerations for digital substation applications

2023 76th Annual Conference for Protective Relay Engineers (CFPR), 2023
Essential for the power industry's move towards digital substations is empowered by reliable data communication infrastructure designed for the exchange of digital information between intelligent electronic device (IEDs), primary switchgear and other ...
Jake Groat   +2 more
semanticscholar   +1 more source

Early Detection of GOOSE Denial of Service (DoS) Attacks in IEC 61850 Substations

IEEE International Conference on Smart Grid Communications, 2022
The availability of communication in IEC 61850 substations can be hindered by Denial of Service (DoS) that result from an advanced Generic Object Oriented Substation Event (GOOSE) poisoning attacks.
Ghada Elbez, K. Nahrstedt, V. Hagenmeyer
semanticscholar   +1 more source

GOOSE Protocol: IED's Smart Solution for Victoria University Zone Substation (VUZS) Simulator Based on IEC61850 Standard

IEEE PES Asia-Pacific Power and Energy Engineering Conference, 2018
The IEC 61850 standard platform is so influential in the world of Substation Automation Systems (SAS). The power industry is seeking a universal communication standard to enable interoperability and integration of Intelligent Electronic Devices (IEDs) in
Joevis J Claveria, Akhtar Kalam
semanticscholar   +1 more source

Design and Demonstration of an IEC 61850-Based Distribution Substation Using Digital Twin Technology

2025 IEEE 1st International Conference on Smart and Sustainable Developments in Electrical Engineering (SSDEE)
The digital twin of a substation provides a virtual model that leverages real-time data from Intelligent Electronic Devices (IEDs) to enhance operational efficiency and support data-driven decision-making.
S. Jha, S. Samantaray, Deepak Kumar
semanticscholar   +1 more source

Zero-shot GOOSE Anomaly Detection via Multi-gate Mixture-of-Experts with Pre-Trained Large Language Model

2025 IEEE Kiel PowerTech
Detecting anomalies in smart grids is vital to safeguarding systems from attacks and failures. As critical components in IEC 61850-based substation communication, Generic Object-Oriented Substation Event (GOOSE) messages are particularly vulnerable to ...
Yi Li   +4 more
semanticscholar   +1 more source

Home - About - Disclaimer - Privacy