Results 151 to 160 of about 153,444 (258)

Investigating the Direct Use of Manganese‐Rich Mixed‐Olivine Cathode in Sodium Battery

open access: yesBatteries &Supercaps, Volume 9, Issue 8, August 2026.
Electrochemically driven Li+/Na+ ion exchange enables the direct use of Li‐based LMFP in Na‐metal cells. Operando/ex situ XAS and PXRD reveal the progressive transformation from LMFP to Na‐triphylite NMFP during cycling. The resulting sodium‐based phase exhibits stable electrochemical performance and compatibility with safer polymer‐electrolyte Na ...
Luca Minnetti   +8 more
wiley   +1 more source

Altered Evening Aperiodic Activity and Microstate Dynamics in Insomnia Disorder: An OPM MEG Study

open access: yesCNS Neuroscience &Therapeutics, Volume 32, Issue 8, August 2026.
Using wearable OPM‐MEG, this study characterized evening and morning resting state neurophysiology in insomnia disorder. A flatter evening aperiodic spectral exponent suggested relatively elevated cortical excitability, alongside altered microstate dynamics involving putative limbic and sensorimotor network states.
Feng Cui   +13 more
wiley   +1 more source

The Value of the ALBI and ALBI–PLT Scores in Predicting Esophageal Varices in Cirrhotic Patients: A Cross‐Sectional Study

open access: yesHealth Science Reports, Volume 9, Issue 8, August 2026.
ABSTRACT Background and Aims Esophageal varices (EVs) are a common and life‐threatening complication of liver cirrhosis. Endoscopic screening is recommended but remains invasive and resource‐intensive. This study aimed to evaluate the diagnostic performance of the albumin–bilirubin (ALBI) and ALBI–platelet (ALBI–PLT) scores for predicting the presence ...
Thang Dinh Nguyen   +2 more
wiley   +1 more source

Accurate Sizing and Resolution of Nominal 200 nm Diameter Polystyrene Nanospheres With Charge Detection Mass Spectrometry

open access: yesSmall, Volume 22, Issue 43, 3 August 2026.
This study highlights the utility of charge detection mass spectrometry (CDMS) as a high‐throughput nanoparticle characterization tool. CDMS measurements of 200 nm polystyrene size standards are within 1% of those derived from transmission electron microscopy (TEM). Notably, a mixture of three ∼200 nm samples is readily resolved by CDMS but not by TEM,
Veena S. Avadhani   +2 more
wiley   +1 more source

An anomalous positron abundance in cosmic rays with energies 1.5–100 GeV

open access: yesNature, 2009
O. Adriani   +50 more
semanticscholar   +1 more source

The origin of the 95 GeV excess in the flavor-dependent $$U(1)_X$$ U ( 1 ) X model

open access: yesEuropean Physical Journal C: Particles and Fields
This study investigates the excesses observed in the CMS diphoton and ditau data around $$95~{\textrm{GeV}}$$ 95 GeV within the framework of the flavor-dependent $$U(1)_X$$ U ( 1 ) X model.
Zhao-feng Ge, Feng-Yan Niu, Jin-Lei Yang
doaj   +1 more source

Correlating XENON and LHC Open Data: Evidence for ∼65 GeV, ∼95 GeV, and ∼110 GeV Dark Matter Candidates

open access: yes
Dataset Description This dataset accompanies the manuscript “Correlating XENON and LHC Open Data: Evidence for ∼12.16 GeV, ∼65 GeV, ∼95 GeV, ∼110 GeV and ∼195 GeV Dark Matter Candidates.” It provides all raw and processed data, analysis scripts, fit results, and figure/table source files needed to reproduce the key correlation studies between XENON1T ...
openaire   +1 more source

Extreme Heat and Rainfall Risk Attributed to Cumulative CO2 Emissions From Fossil Fuel Producers

open access: yesEarth's Future, Volume 14, Issue 8, August 2026.
Abstract Legal and political approaches to climate accountability require demonstrating that a particular emitter contributed to a climate impact, but quantitative solutions to this attribution challenge remain nascent. This study leverages the proportionality of global warming to cumulative CO2 emissions to develop statistical models that directly ...
Christopher W. Callahan
wiley   +1 more source

Latitude Survey of Neutrons and Muons to Determine Cosmic Ray Neutron Sensing Yield Functions

open access: yesJournal of Geophysical Research: Space Physics, Volume 131, Issue 8, August 2026.
Abstract Cosmic Ray Neutron Sensing (CRNS) is a ground‐based technique that utilizes epithermal neutron measurements as a proxy for environmental hydrogen content. Similarly to other ground‐based cosmic ray detectors (e.g., neutron monitors), CRNS detectors are affected by the solar cycle and space weather events.
Lasse Hertle   +16 more
wiley   +1 more source

Measurement of +⁢−→⁢/ cross section from √=3.808  GeV to 4.951 GeV

open access: yesPhysical Review D
Using data samples with an integrated luminosity of 22.42 fb-1 collected by the BESIII detector operating at the BEPCII storage ring, we measure the cross sections of the e+e-→ηJ/ψ process at center-of-mass energies from 3.808 to 4.951 GeV. Three structures are observed in the line shape of the measured cross sections.
Ablikim, M.   +12 more
openaire   +1 more source

Home - About - Disclaimer - Privacy