Results 81 to 90 of about 798 (204)
Microwave stress monitoring using Co-rich amorphous microwire assessed by free space measurements
We provide new experimental results on studies of the effect of applied stress on Reflection coefficient (S22 parameter) of Co-rich glass-coated ferromagnetic microwire measured using free space microwave spectroscopy.
Valentina Zhukova +2 more
doaj +1 more source
A Study on Giant Magnetoimpedance Effect in VITROVAC 6025Z Micro-patterned Ribbons
In this paper, micro-patterned cobalt-based amorphous ribbons with different structures are fabricated by MEMS technology, including bonding, lithography and electroplating.
Yang Zhen, Fan Tianqi, Lei Chong
doaj +1 more source
Hydrogels are biomimetic materials widely used in the area of biomedical engineering and biosensing. Ferrogels (FG) are magnetic composites capable of functioning as magnetic field sensitive transformers and field assisted drug deliverers.
Felix A. Blyakhman +9 more
doaj +1 more source
Magnetic biosensors are an important part of biomedical applications of magnetic materials. As the living tissue is basically a “soft matter.” this study addresses the development of ferrogels (FG) with micron sized magnetic particles of magnetite and ...
Alexander P. Safronov +8 more
doaj +1 more source
Systematic measurements of giant magnetoimpedance (GMI) and its relaxation (magnetoimpedance aftereffect, MIAE) have been carried out on a series of Go-rich amorphous ribbons with different magnetostriction constant, before and after the induction of ...
Barandiaran, JM +4 more
core +1 more source
Giant magnetoimpedance (GMI) effect is a powerful technique for magnetic label detection. Co-based amorphous ribbons are cheap materials showing high GMI effect at low operation frequencies for close to zero magnitostriction compositions.
Lotfollahi Zahra +3 more
doaj +1 more source
DC and AC linear magnetic field sensor based on glass coated amor- phous microwires with Giant Magnetoimpedance [PDF]
Giant Magnetoimpedance (GMI) effect has been studied in amorphous glass-coated microwires of composition (Fe6Co94)(72.5)Si12.5B15. The impedance of a 1.5 cm length sample has been characterized by using constant AC currents in the range of 400 mu A-4 mA ...
García Miquel, Ángel Héctor +1 more
core +1 more source
Giant magnetoimpedance of amorphous ribbon/Cu/amorphous ribbon trilayer microstructures
The giant magnetoimpedance (GMI) and giant magnetoresistance (GMR) of amorphous ribbon/Cu/amorphous ribbon trilayer microstructures, based on Metglas(TM) 2714a ribbons and Cu foils, is measured and analyzed. We obtain GMI and GMR ratios of 830% and 2630%,
Amalou, F., Gijs, M. A. M.
core +1 more source
National Natural Science Foundation of China [20575022, 60776066]; National Science Foundation for Young Scientists of China,; Natural Science Foundation of Fujian Province [A0810019]; Undergraduates' Innovation Experimental Program; Key Project of ...
Li, S. P. +9 more
core
Enhancement of Magnetoimpedance in Fe
With increasing Cu content x in Fe 74:5Àx Cu x Nb 3 Si 13:5 B 9 as cast ribbons, an enhancement of magnetoimpedance can be observed. The magnetoimpedance ðZðHÞ À Zð0ÞÞ=Zð0Þ for Fe 72 Cu 2:5 Nb 3 Si 13:5 B 9 as cast ribbon reaches À35% under a dc field H ...
Hongwei Qin +3 more
core

