Results 281 to 290 of about 6,266,802 (357)
Some of the next articles are maybe not open access.
Physica Scripta, 2022
Under DC voltage, the interface charge of the spacer in gas-insulated metal-enclosed transmission lines (GIL) and gas-insulated metal-enclosed switchgear (GIS) is prone to accumulate, and the charge is an important factor to induce surface flashover.
Shaocong Wu +7 more
semanticscholar +1 more source
Under DC voltage, the interface charge of the spacer in gas-insulated metal-enclosed transmission lines (GIL) and gas-insulated metal-enclosed switchgear (GIS) is prone to accumulate, and the charge is an important factor to induce surface flashover.
Shaocong Wu +7 more
semanticscholar +1 more source
IEEE transactions on dielectrics and electrical insulation, 2021
A multi-physics simulation model of the tri-post insulator in ±800 kV GIL laid horizontally is established to study the effects of gas convection on surface charges and electric field distribution.
B. Du +4 more
semanticscholar +1 more source
A multi-physics simulation model of the tri-post insulator in ±800 kV GIL laid horizontally is established to study the effects of gas convection on surface charges and electric field distribution.
B. Du +4 more
semanticscholar +1 more source
Multidimensional Functionally Graded Materials (ε/σ-MFGM) for HVDC GIL/GIS Spacers
IEEE transactions on dielectrics and electrical insulation, 2022This study discusses the multidimensional functionally graded materials (MFGMs) for spacers in high voltage direct current gas-insulated transmission lines and switchgears (HVDC GILs/GISs). The effects of surface conductance graded materials ( $\sigma $ -
B. Du +3 more
semanticscholar +1 more source
Surface Charge Characteristics of DC-GIL Insulator Under Multiphysics Fields: 3-D Modeling
IEEE transactions on dielectrics and electrical insulation, 2022Surface charge accumulation on the insulator of direct current gas-insulated transmission lines (DC-GILs) under thermal-electric multiphysics fields is investigated using the finite element method (FEM).
Xiaolong Li +3 more
semanticscholar +1 more source
IEEE transactions on dielectrics and electrical insulation, 2021
In this paper, an electro-thermal based surface charge accumulation model is established. Heat conduction, heat convection and heat radiation are included.
Yi Luo, Ju Tang, Zijun Pan, C. Pan
semanticscholar +1 more source
In this paper, an electro-thermal based surface charge accumulation model is established. Heat conduction, heat convection and heat radiation are included.
Yi Luo, Ju Tang, Zijun Pan, C. Pan
semanticscholar +1 more source
IEEE Transactions on Instrumentation and Measurement, 2021
Partial discharge (PD) detection and localization is one of the most effective methods in gas-insulated transmission lines (GIL) insulation fault diagnosis, which is important to the early troubleshooting and safe operation. Compared with the widely used
Y. Zang +6 more
semanticscholar +1 more source
Partial discharge (PD) detection and localization is one of the most effective methods in gas-insulated transmission lines (GIL) insulation fault diagnosis, which is important to the early troubleshooting and safe operation. Compared with the widely used
Y. Zang +6 more
semanticscholar +1 more source
IEEE transactions on dielectrics and electrical insulation, 2021
The demand for DC gas-insulated switchgear/gas-insulated transmission line (GIS/GIL) becomes more and more urgent in recent years owing to the rapid development of high voltage direct current (HVDC) transmission systems.
Feng Wang +5 more
semanticscholar +1 more source
The demand for DC gas-insulated switchgear/gas-insulated transmission line (GIS/GIL) becomes more and more urgent in recent years owing to the rapid development of high voltage direct current (HVDC) transmission systems.
Feng Wang +5 more
semanticscholar +1 more source
High Voltage, 2021
Key Technology for Environmentally Friendly Gas‐ In, Grant/Award Number: 2017YFB0902500 Abstract Partial discharge (PD) is one of themain causes rendering the deterioration of the insulation state in gas‐insulated transmission line (GIL).
Y. Zang +5 more
semanticscholar +1 more source
Key Technology for Environmentally Friendly Gas‐ In, Grant/Award Number: 2017YFB0902500 Abstract Partial discharge (PD) is one of themain causes rendering the deterioration of the insulation state in gas‐insulated transmission line (GIL).
Y. Zang +5 more
semanticscholar +1 more source
IEEE transactions on dielectrics and electrical insulation
The metal dust moving inside the HVDC GIS/GIL will be easily adsorbed to the surface of the insulator and cause surface discharge. The study of the movement and adsorption characteristics of metal dust is extremely important.
Yutong Zhang +7 more
semanticscholar +1 more source
The metal dust moving inside the HVDC GIS/GIL will be easily adsorbed to the surface of the insulator and cause surface discharge. The study of the movement and adsorption characteristics of metal dust is extremely important.
Yutong Zhang +7 more
semanticscholar +1 more source
SAFE-GIL: SAFEty Guided Imitation Learning for Robotic Systems
IEEE International Conference on Robotics and AutomationBehavior cloning (BC) is a widely used approach in imitation learning where a robot learns a control policy by observing an expert supervisor. However the learned policy can make errors and might lead to safety violations which limits their utility in ...
Yusuf Umut Ciftci +4 more
semanticscholar +1 more source

