Results 281 to 290 of about 7,162,114 (343)
As the transmission capacity of gas insulated transmission line (GIL) increases, the synergistic improvement in dielectric and mechanical strengths of GIL insulators is urgently needed for the development of advanced power systems.
He Li, Qing Wang
exaly +2 more sources
Some of the next articles are maybe not open access.
Related searches:
Related searches:
IEEE transactions on dielectrics and electrical insulation, 2020
In this paper, the surface nonlinear conductivity (SNC) spacer is proposed to regulate the electric field in a 500 kV DC-GIL, whose effects are verified by assigning a temperature gradient, a rough electrode, a metal particle and a polarity reversal ...
H. C. Liang, B. Du, J. Li
semanticscholar +1 more source
In this paper, the surface nonlinear conductivity (SNC) spacer is proposed to regulate the electric field in a 500 kV DC-GIL, whose effects are verified by assigning a temperature gradient, a rough electrode, a metal particle and a polarity reversal ...
H. C. Liang, B. Du, J. Li
semanticscholar +1 more source
Mechanical Stress Distribution and Reliability Analysis of GIL Tri-post Insulator
International Conference on Electrical Materials and Power Equipment, 2021Tri-post insulator is the key insulation component of UHV and EHV gas insulated transmission pipeline (GIL), and its mechanical reliability is directly related to the operation safety of GIL.
Songtao Liu +5 more
semanticscholar +1 more source
International Journal of Electrical Power & Energy Systems, 2019
Under AC, DC and switching impulse voltages, the surface charges accumulated on the basin insulators of Gas Insulated Substation (GIS) or Gas Insulated Metal Enclosed Transmission Line (GIL) could distort local electric field and even reduce the surface ...
B. Qi, C. Gao, Chengrong Li, Jun Xiong
semanticscholar +1 more source
Under AC, DC and switching impulse voltages, the surface charges accumulated on the basin insulators of Gas Insulated Substation (GIS) or Gas Insulated Metal Enclosed Transmission Line (GIL) could distort local electric field and even reduce the surface ...
B. Qi, C. Gao, Chengrong Li, Jun Xiong
semanticscholar +1 more source
, 2020
Prediction and analysis of cutting tool wear in dense sandy ground is important for improving the working performance of slurry shield TBM, especially for long-distance cross-river tunnel. Appropriate prognosis model can not only improve the construction
Tang Shaohui +7 more
semanticscholar +1 more source
Prediction and analysis of cutting tool wear in dense sandy ground is important for improving the working performance of slurry shield TBM, especially for long-distance cross-river tunnel. Appropriate prognosis model can not only improve the construction
Tang Shaohui +7 more
semanticscholar +1 more source
High-Resolution Temperature Distribution Measurement of GIL Spacer Based on OFDR and Ultraweak FBGs
IEEE Transactions on Instrumentation and Measurement, 2020The temperature distribution on the gas-insulated line (GIL) spacer affects surface charge accumulation. However, the spacer temperature distribution is hard to measure because the conventional electric sensors are large dimensions, hard to multiplex ...
G. Ma +6 more
semanticscholar +1 more source
, 2020
Surface charging phenomena on DC GIL spacers is a complicated process affected by lots of factors, among which surface conductivity is an important dielectrics parameter. In this study, experimental and theoretical research are carried out to investigate
Jianyi Xue +5 more
semanticscholar +1 more source
Surface charging phenomena on DC GIL spacers is a complicated process affected by lots of factors, among which surface conductivity is an important dielectrics parameter. In this study, experimental and theoretical research are carried out to investigate
Jianyi Xue +5 more
semanticscholar +1 more source
Electrical field distribution along SG6/N2 filled DC-GIS/GIL epoxy spacer
IEEE transactions on dielectrics and electrical insulation, 2018The flashover faults due to the accumulation of surface charge have restricted the further development of spacers in HVDC GIS/GIL transmission systems.
B. Du, H. C. Liang, J. Li, Z. Ran
semanticscholar +1 more source
Applied Soft Computing, 2018
Failure mode and effects analysis (FMEA) as a useful tool in safety and reliability analysis to identify and eliminate known or potential failures from the process of product design, development and production has been widely used in a variety of ...
Zhen Wang +5 more
semanticscholar +1 more source
Failure mode and effects analysis (FMEA) as a useful tool in safety and reliability analysis to identify and eliminate known or potential failures from the process of product design, development and production has been widely used in a variety of ...
Zhen Wang +5 more
semanticscholar +1 more source

