Imaging of Glaucoma Drainage Devices

Journal of Computer Assisted Tomography, 2012
Previously reserved for patients with refractory glaucoma, glaucoma drainage devices (GDDs) are being used more frequently as a primary treatment option. Several types of GDDs are currently manufactured, only one of which is radiopaque. Knowledge of their typical imaging appearance in addition to pertinent background information is therefore vital for ...
Michael, Reiter   +3 more
openaire   +2 more sources

Glaucoma drainage devices: pros and cons

Current Opinion in Ophthalmology, 1999
Glaucoma drainage devices are an option in the management of complicated glaucomas that carry a high risk of failure from conventional filtering surgery. Examples include the glaucomas associated with aphakia or pseudophakia, neovascular glaucoma, and glaucomas associated with trauma, uveitis, epithelial downgrowth, iridocorneal endothelial syndrome ...
M H, Assaad, G, Baerveldt, E J, Rockwood
openaire   +2 more sources

Implantation of a second glaucoma drainage device

Graefe's Archive for Clinical and Experimental Ophthalmology, 2017
To evaluate success rates in controlling intraocular pressure (IOP) after implantation of a second glaucoma drainage device (GDD) with a Baerveldt glaucoma implant in patients with refractory glaucoma, with a secondary aim of reducing the need for postoperative glaucoma medications.This retrospective, noncomparative, interventional study included ...
Francis, Brian A.   +6 more
openaire   +3 more sources

Novel Micromachined Valved Glaucoma Drainage Devices

2006 International Conference of the IEEE Engineering in Medicine and Biology Society, 2006
In this work two novel valve devices are proposed for treatment of glaucoma. By opening or closing, the proposed valves can be used to reduce high pressures in the eye (hypertony), or prevent low pressures in the eye (hypotony) respectively. These devices work based on the buckling of fluid channel connected to the anterior chamber of the eye.
Kouhyar Tavakolian   +2 more
openaire   +2 more sources

Use of glaucoma drainage devices in the management of glaucoma associated with aniridia

American Journal of Ophthalmology, 2003
To describe intraocular pressure (IOP) and visual acuity outcomes after glaucoma drainage device placement in eyes with glaucoma associated with aniridia.Retrospective, noncomparative, consecutive, interventional case series.The medical records of all patients who underwent glaucoma drainage device placement for the management of glaucoma associated ...
Claudia P, Arroyave   +4 more
openaire   +2 more sources

Glaucoma Drainage Devices

2023
Karthikeyan Mahalingam   +2 more
openaire   +2 more sources

Trainee Glaucoma Surgery: Experience with Trabeculectomy and Glaucoma Drainage Devices

Ophthalmic Surgery, Lasers and Imaging Retina, 2010
Background and Objective: To examine outcomes of trabeculectomy with mitomycin C and glaucoma drainage device placement for uncontrolled glaucoma when performed by resident surgeons. Patients and Methods: This study included any patient who underwent a trabeculectomy with mitomycin ...
Michael A, Connor   +3 more
openaire   +2 more sources

The Long-term Outcomes of Glaucoma Drainage Device in Pediatric Glaucoma

Journal of Glaucoma, 2016
To evaluate the long-term outcomes and safety of glaucoma drainage device (GDD) in pediatric patients.Retrospective, noncomparative study including all patients below 18 years old who underwent Baerveldt or Molteno GDD implantation by a single surgeon. Mitomycin-C was used in most cases.
Achilleas, Mandalos   +3 more
openaire   +2 more sources

Simultaneous placement of 2 glaucoma drainage devices for uncontrolled glaucoma

Canadian Journal of Ophthalmology, 2014
To report baseline characteristics and surgical outcomes of placement of simultaneous glaucoma drainage devices (GDDs) in eyes with considerably elevated intraocular pressure (IOP) despite maximal medical therapy.Retrospective case series.Twelve eyes of 12 patients underwent simultaneous placement of a Baerveldt 350 GDD and an Ahmed S3 GDD in the same ...
Anna C, Momont   +3 more
openaire   +2 more sources