Results 111 to 120 of about 903,590 (280)

Restoring Endothelial Mitochondrial Homeostasis With a Bioactive Nanoshield Promotes Vascular Regeneration on Cardiovascular Implants

open access: yesAdvanced Science, EarlyView.
A bioactive poly(citrate‐polyglycol‐procyanidin) (PCGP) nanoshield is developed for cardiovascular implants to restore endothelial mitochondrial homeostasis following vascular injury. By preserving mitochondrial integrity, re‐establishing metabolic balance, and activating PI3K/Akt/eNOS‐NO signaling, the PCGP interface promotes functional endothelial ...
Xiyu Liu   +14 more
wiley   +1 more source

One-step detection of hexokinase activity using a personal glucose meter

open access: yes, 2018
Using commercially available personal glucose meters for the determination of hexokinase activity.
Liyan Liu   +4 more
core   +1 more source

Therapeutic avenues and prospects of blood glucose self-monitoring, the essential component of diabetes mellitus management

open access: yesКлинический разбор в общей медицине
Diabetes mellitus (DM) is one of the global problems of world’s healthcare. Systemic vascular complications are the dangerous sequelae of the disease, and chronic hyperglycemia is the leading factor contributing to the disease development.
Elena V. Biryukova
doaj   +1 more source

Sex‐ and Time‐Resolved Physiological and Gut Ecosystem Responses to a Food‐Grade Microbiome‐Targeted Intervention in Collegiate Endurance Athletes

open access: yesAdvanced Science, EarlyView.
In collegiate endurance athletes, a 6‐week randomized CPYE intervention yielded time‐ and sex‐dependent shifts in field‐based cardiorespiratory, metabolic, and redox indices, accompanied by changes in gut multi‐omics profiles. An exploratory extension during intensified training generates hypotheses warranting future validation.
Meng Zhang   +8 more
wiley   +1 more source

Can one point-of-care glucose meter be used for all pediatric and adult hospital patients? Evaluation of three meters, including recently modified test strips

open access: yes, 2011
Background: Within hospitals, bedside blood glucose measurements are widely used for investigating suspected hyper- or hypoglycemia, monitoring diabetes, and adjusting glucose-lowering medication.
Nita Buckingham   +11 more
core   +1 more source

Differences in the system accuracy acceptability of four types of blood glucose monitoring systems against five different standards

open access: yesiLABMED
Objective This study aimed to evaluate the system accuracy of four types of blood glucose monitoring systems (BGMSs) and explore the differences in the system accuracy acceptability of each BGMS against five different standards.
Tengjiao Wang   +8 more
doaj   +1 more source

Self‐Propelled HPB@Lip@AB Nanomotors Ameliorate Dry Eye Disease

open access: yesAdvanced Science, EarlyView.
A self‐propelled HPB@Lip@AB nanomotor system is developed for dry eye disease (DED) therapy, facilitating rapid penetration across ocular surface barriers while integrating hydrogen therapy with multi‐enzyme‐like antioxidant activity. The nanoplatform restores mitochondrial function, suppresses oxidative stress, inflammation, and apoptosis, and ...
Jing Li   +9 more
wiley   +1 more source

Usability Evaluation of Blood Glucose Meters for Elderly Diabetic Patients

open access: yes, 2016
In the context of this study the usability of the first blood glucose meter that is connectable to a smartphone has been investigated by the use through diabetic patients of different ages and with different technical experiences.
Mertens, Alexander   +18 more
core   +1 more source