TECHNIQUE FOR IMPROVING THE ANALYTICAL CHARACTERISTICS OF BIOSENSORS BASEDON ENZYMES OF THE OXIDASE SUBCLASS [PDF]
Aim. In this study, the possibility of improving the analytical performance of a monoenzyme biosensor based on the main oxidase pathway by adding catalase to bioselective membranes was increased.
K.O. BERKETA +3 more
doaj +1 more source
Nano-yarn carbon nanotube fiber based enzymatic glucose biosensor [PDF]
This is the author's accepted manuscript. The final published article is available from the link below. Copyright @ 2010 IOP Publishing Ltd.A novel brush-like electrode based on carbon nanotube (CNT) nano-yarn fiber has been designed for electrochemical ...
Song, W +5 more
core +1 more source
Glucose oxidase (EC 1.1.3.4) sensors that have been developed and widely used for glucose monitoring have generally relied on electrochemical principle.
Ying Chuin Yee +3 more
doaj +1 more source
Genipin is used to simultaneously crosslink chitosan, amine-containing osmium redox complex and glucose oxidase on graphite disks to produce enzyme-based electrodes for glucose oxidation.
Peter Ó. Conghaile +3 more
doaj +1 more source
Time-resolved quantitative assays and imaging of enzymes and enzyme substrates using a new europium fluorescent probe for hydrogen peroxide [PDF]
The thesis describes the development of a novel reversible H2O2 fluorescent probe comprising the ternary complex of europium(III), tetracycline and hydrogen peroxide; and its application in the assays of H2O2, of H2O2 producing oxidases and their ...
Wu, Meng
core +1 more source
Engineering Galactose Oxidase to Increase Expression Level in E. coli, Enhance Thermostability and Introduce Novel Activities [PDF]
For the first time, we functionally expressed the fungal glycosylated copper-containing enzyme, galactose oxidase, in Escherichia coli. The generation of fully functional GOase confirms that the formation of the unusual thioether bond is an auto ...
Sun, Lianhong
core +1 more source
In Silico Analysis of Glucose Oxidase H516r and H516d Mutations for an Enzymatic Fuel Cell
Glucose oxidase (GOx) is an oxido-reductase enzyme that catalyzes glucose into hydrogen peroxide and glucono delta-lactone (GDL). GOx has the potential to be used in the medical field.
Puspa Julistia Puspita +3 more
doaj +1 more source
Glucose Oxidase Loading in Ordered Porous Aluminosilicates: Exploring the Potential of Surface Modification for Electrochemical Glucose Sensing [PDF]
Enzymatic electrochemical sensors have become the leading glucose detection technology due to their rapid response, affordability, portability, selectivity, and sensitivity.
Ioannis, Papakonstantinou +4 more
core +2 more sources
Biosensing Membrane Base on Ferulic Acid and Glucose Oxidase for an Amperometric Glucose Biosensor
A biosensing membrane base on ferulic acid and glucose oxidase is synthesized onto a carbon paste electrode by electropolymerization via cyclic voltammetry in aqueous media at neutral pH at a single step.
Gabriela Valdés-Ramírez, Laura Galicia
doaj +1 more source
Glucose Oxidase Immobilization on TMAH-Modified Bentonite
The influence of bentonite modification by tetramethyl ammonium hydroxide (TMAH) on its capability to immobilize glucose oxidase (GOX) was studied. Modification of bentonite was conducted by the adding of 0-5% (v/v) TMAH.
Ruth Chrisnasari +3 more
doaj +1 more source

