A national survey of diagnostic tests reported by UK community optometrists for the detection of chronic open angle glaucoma [PDF]
Purpose: In the UK, the majority of cases of chronic open angle glaucoma are detected by community optometrists following a routine sight test. However, there is potential for variability in case finding strategies used.
Edgar, DF +4 more
core +1 more source
To compare intraocular pressure (IOP) measurements obtained using the Topocon noncontact tonometer (NCT), the Goldmann applanation tonometer (GAT), and the Corvis ST (CST), a newly developed tonometer with features of visualization and measurement of the corneal deformation response to an air impulse.
Jiaxu, Hong +6 more
openaire +2 more sources
Smart molecules in ophthalmology: Hydrogels as responsive systems for ophthalmic applications
The provided schematic of the human eye highlights the multifaceted applications of hydrogels in ophthalmology: Topical Administration, targeted at the corneal surface; Soft contact lenses, demonstrating biocompatibility and permeability; Adhesives for wound repair, utilized for ocular surface injuries; Vitreous substitutes, an alternative to the ...
Merve Kulbay +3 more
wiley +1 more source
Okuläre Pulsamplitude als biometrischer Messwert in der Glaukomdiagnostik [PDF]
Zusammenfassung: Hintergrund: Die dynamische Konturtonometrie (DCT) ermöglicht direkte transkorneale Messungen des Augeninnendrucks und der okulären Pulsamplitude (OPA).
Bachmann, L.M. +3 more
core
IOP variations in the sitting and supine positions [PDF]
Purpose: The aim of this study was to assess the influence of the position (upright vs. supine) in the intraocular pressure (IOP) measured with a non-contact portable tonometer.
González-Méijome, José Manuel +6 more
core +1 more source
The prevalence of glaucoma in a 70‐year‐old Swedish population in the city area of Gothenburg
Abstract Purpose To determine the prevalence of and risk factors for open‐angle glaucoma in a population of 70‐year‐olds in Gothenburg, Sweden and to compare the visual function between the glaucoma population and the non‐glaucoma population. Methods Of the entire cohort (n = 1203), 1182 participants responded a questionnaire on self‐reported glaucoma ...
Lena Havstam Johansson +4 more
wiley +1 more source
Comparing intraocular pressures with different types of tonometers and its correlation with central corneal thickness in patients presenting in a tertiary care centre [PDF]
Background & Aims: Glaucoma usually undiagnosed in general population. People usually ignores the symptoms and came late when disease already get worsened. This study aimed to compare intraocular pressures in general population having inclusion criteria
Priyanka J.Kharadi +2 more
doaj
Coupled Biomechanical Response of the Cornea Assessed by Non-Contact Tonometry. A Simulation Study [PDF]
The mechanical response of the cornea subjected to a non-contact air-jet tonometry diagnostic test represents an interplay between its geometry, the corneal material behavior and the loading.
Ariza-Gracia, Miguel Á. +4 more
core +6 more sources
Introduction: Goldmann applanation tonometer (GAT) is the gold standard for Intraocular Pressure (IOP) measurement but has disadvantage of being contact device and problems with portability.
Shalini Mohan +4 more
doaj +1 more source
Intraocular pressure profile during the modified diurnal tension curve using Goldman applanation tonometry and dynamic contour tonometry [PDF]
The aim of this study was to compare the intraocular pressure (IOP) profile during the modified diurnal tension curve (mDTC) using Goldman applanation tonometry (GAT) and dynamic contour tonometry (DCT) in treated glaucomatous eyes.
Alan Kardec Barreira +5 more
core +2 more sources

