The utility of rebound tonometer in late elderly subjects

open access: yesClinical Interventions in Aging, 2014
Rei Sakata,1,2 Jiro Numaga1 1Tokyo Metropolitan Geriatric Hospital, Tokyo, Japan; 2Department of Ophthalmology, University of Tokyo, Graduate School of Medicine, Tokyo, Japan Background: To compare intraocular pressure (IOP) readings using the Icare ...
Sakata R, Numaga J
doaj  

Measuring accurate IOPs: Does correction factor help or hurt?

open access: yesClinical Ophthalmology, 2010
Pinakin Gunvant1, Robert D Newcomb2, Elliot M Kirstein3, Victor E Malinovsky4, Richard J Madonna5, Richard E Meetz 41Southern College of Optometry, Memphis, Tennessee, USA; 2The Ohio State University College of Optometry, Columbus, Ohio, USA; 3The ...
Pinakin Gunvant   +3 more
doaj  

Comparison of intraocular pressure measurement between Goldmann applanation tonometer and Tonopen

open access: yesAsian Journal of Medical Sciences
Background: Primary open-angle glaucoma (POAG) is a chronic optic neuropathy causing visual field loss and open angles. It accounts for 90% of glaucoma cases and is linked to raise intraocular pressure (IOP). POAG is the most common type of glaucoma.
Sabita Dhakal   +3 more
doaj   +1 more source

Prevalence of calibration errors in goldmann applanation tonometers.

open access: yesJournal of ophthalmic & vision research, 2012
To determine the prevalence of calibration errors in Goldmann applanation tonometers at Farabi Eye Hospital.This cross-sectional study was performed on all tonometers in use at Farabi Eye Hospital. All Haag-Streit Goldmann applanation tonometers were checked according to the manufacturer's method by two independent observers and by a third observer in ...
Heydar, Amini   +7 more
openaire   +1 more source

Applanation pressure function in Goldmann tonometry and its correction [PDF]

open access: yes, 2013
So far applanation tonometry has not worked out any theoretical basis for correcting the result of intraocular pressure measurement carried out on a cornea with noncalibration dimensions by means of the Goldmann tonometer.
Śródka, W.
core  

Comparison of three methods of tonometry in normal subjects: Goldmann applanation tonometer, non-contact airpuff tonometer, and Tono-Pen XL

open access: yesClinical Ophthalmology, 2014
Ihsan Yilmaz, Cigdem Altan, Ebru Demet Aygit, Cengiz Alagoz, Okkes Baz, Sibel Ahmet, Semih Urvasizoglu, Dilek Yasa, Ahmet DemirokBeyoglu Eye Training and Research Hospital, Istanbul, TurkeyObjective: We aimed to compare intraocular pressure (IOP ...
Yilmaz I   +8 more
doaj  

COMPARISON OF INTRAOCULAR PRESSURE MEASURED WITH GOLDMANN APPLANATION TONOMETER AND NON-CONTACT AIR-PUFF TONOMETER

open access: yesGomal Journal of Medical Sciences, 2016
Background: Intraocular pressure measurement (IOP) is of pivotal importance for the diagnosis and management of glaucoma. The objective of this study was to compare intraocular pressure measurement with Goldmann Applanation tonometer (GAT) and non ...
Hidayatullah Mahsud   +4 more
doaj  

Applanation pressure function in Goldmann tonometry and its correction

open access: yes, 2020
So far applanation tonometry has not worked out any theoretical basis for correcting the result of intraocular pressure measurement carried out on a cornea with noncalibration dimensions by means of the Goldmann tonometer.
Wiesław Śródka
core  