Results 1 to 10 of about 157,334 (213)
Study of A Bus Voltage Control Strategy for Two-Way AC/DC Current Converter in DC Microgrid [PDF]
In an isolated DC microgrid consisting of photovoltaic cells, an energy storage unit and load, reasonable control of grid-connected two-way AC/DC converter can effectively realize coordinated power distribution and bus voltage stabilization of the ...
Zheng Ningkang +3 more
doaj +1 more source
Editorial: Grid Connection of Converters in Renewable Applications [PDF]
Energy generated from renewable sources is fed into the grid by means of electronic power converters. These can be supervised at system (grid) level to coordinate all productions points together with storages and loads. Regulations impose power supply quality requirements regarding harmonics, grid fault response and low voltage ride through (LVRT). The
Martinez Rodrigo, Fernando +3 more
openaire +5 more sources
The voltage disturbance in the weak grid will cause frequency coupling and even persistent oscillation of the grid current of grid connected converter in power system.
Qi Wang, Xingyong Zhao, Peng Wang
doaj +1 more source
Steady-state Operation Area of VSC-HVDC Converter Station Connecting Renewable Energy Cluster by Isolated Network [PDF]
When the large-scale renewable power island is connected to VSC-HVDC transmission system, we should figure out the steady-state operation area of VSC-HVDC converter station. Based on the equivalent model of renewable energy island, the constraints of VSC-
Xian Wenyuan +5 more
doaj +1 more source
Aging and temperature changes in the passive components of an LCL-filter grid connected converter system (GCCs) may lead to parameter uncertainties, which can in turn influence its modeling accuracy for finite-control-set model predictive control (FCS ...
Bo Long +5 more
semanticscholar +1 more source
A Simple Sinusoidal Buck Converter Working as A Single-Phase Grid-Connected Inverter
The need for a simple grid-connected inverter is increasing. The integration of a simple buck converter and a push-pull converter to be a grid-connected inverter is presented in this paper.
Hanny H. Tumbelaka
doaj +1 more source
This paper proposes an improved three-stages cascading passivity-based control (PBC) for a grid -connected LCL converter in unbalanced weak grid condition.
Jianguo Li +5 more
doaj +1 more source
Current-Harmonic-Based Active Damping Strategy
The voltage-harmonic-based active damping control (VHBAD) can improve the adaptability of the converter to the weak grid, but it will weaken the suppression ability of background harmonic voltage disturbance and affect the quality of grid-connected ...
Jia XU, Shude YANG, Xinwen ZHANG
doaj +1 more source
A Universal Controller for Grid-Connected Voltage-Source Converters [PDF]
Power-synchronization control (PSC) and vector current control (VCC), the latter including cascaded outer loops, are, respectively, considered to be grid-forming and grid-following schemes. They have significant structural differences. Despite that, it is here shown that the two schemes can be unified by making a series of minor modifications to PSC ...
Harnefors, Lennart +5 more
openaire +4 more sources
Control strategy for direct-drive wind power system under asymmetric grid voltage sag
In view of problems of DC side overvoltage, grid-connected current distortion and grid-connected power fluctuation existed in grid-connected operation of direct-drive wind power system under asymmetric grid voltage sag, superconducting magnetic energy ...
DONG Ruihong +3 more
doaj +1 more source

