Results 251 to 260 of about 54,052 (304)

Dynamic Modulation of OECT-Based Inverters for In Situ Electrophysiological Monitoring. [PDF]

open access: yesAdv Sci (Weinh)
Hu G   +7 more
europepmc   +1 more source

Novel grid-connected photovoltaic inverter

IEE Proceedings - Generation, Transmission and Distribution, 1996
Detailed analysis and simulation results of a novel solar photovoltaic inverter configuration interconnected to the grid are presented. From the simulation results it is confirmed that the harmonic distortion of the output current waveform of the inverter fed to the grid is within the stipulated limits laid down by the utility companies.
SAHA, S, SUNDARSINGH, VP
openaire   +2 more sources

Grid-connected photovoltaic panel via an inverter

2019 19th International Conference on Sciences and Techniques of Automatic Control and Computer Engineering (STA), 2019
This paper presents the modeling for a grid-connected photovoltaic (PV) and the generated power regulation considering the solar irradiation variations and of the temperature. This connection was realized through an inverter followed by a filter to improve the produced energy quality.
Khabou, Hajer   +2 more
openaire   +2 more sources

Zero-crossing distortion in grid-connected PV inverters

IEEE 2002 28th Annual Conference of the Industrial Electronics Society. IECON 02, 2003
Zero-crossing distortion has been observed in the ac output current produced by some grid-connected photovoltaic inverters and this can cause a resonant response between the grid impedance and the inverter filter capacitor. In some cases, particularly with large numbers of parallel-connected inverters and with weak grids, the resonance can cause ...
Kotsopoulos, A.   +2 more
openaire   +3 more sources

Development of 200kW Grid-connected photovoltaic inverter

2007 7th Internatonal Conference on Power Electronics, 2007
This paper presents development of 200 kW grid connected PV inverter. 200 kW Grid connected PV inverter has the utility frequency transformer for the galvanic isolation between DC and AC, and its output is 3-phase 3-wire 60 Hz, 380 V. P&O algorithm is used for the maximum power point tracking (MPPT) and the active frequency drift scheme for the ...
null Young Roc Kim   +4 more
openaire   +1 more source

Universal Single-Stage Grid-Connected Inverter

IEEE Transactions on Energy Conversion, 2008
A new single-stage grid-connected inverter, suitable for distributed generation applications, is proposed. The inverter is universal in the sense that it can be switched between buck, boost, and buck--boost configurations by appropriately altering the pulse width modular (PWM) control.
PRASAD, BS, JAIN, SACHIN, AGARWAL, VIVEK
openaire   +2 more sources

Dynamics of grid connected PV inverters

2010 IEEE International Energy Conference, 2010
Power failure of electric network identifies the hazardous aspects of inverter grid interfacing to linesmen maintaining power lines. Dynamics of grid-connected first order system indicates the necessity for an optimum tripping mechanism for an inverter feeding diversity of locally connected loads are analysed.
Khalid Hasan Masoud, Gerard Ledwich
openaire   +1 more source

A grid connected current source inverter.

2009 International Conference on Clean Electrical Power, 2009
In Co-generation systems are required converters able to inject current with low harmonic content, traditionally the inverters are considered. In this paper is proposed to use the current source inverter instead of voltage source inverter, this type of inverters can accept a low input voltage to inject current to the ac mains. The operation, simulation
N. Vazquez   +5 more
openaire   +1 more source

Grid Connected PV System Using Multilevel Inverter

2021 7th International Conference on Electrical Energy Systems (ICEES), 2021
The system is designed to feed the solar energy into a single-phase utility grid. The output frequency and voltage magnitude of the Multilevel Inverter (MLI) is regulated to track the grid frequency and voltage in such a way that Unity Power Factor (UPF) is always maintained.
Deepak Kumar Singh   +2 more
openaire   +1 more source

Home - About - Disclaimer - Privacy