Results 31 to 40 of about 54,052 (304)

Suppression of line voltage related distortion in current controlled grid connected inverters [PDF]

open access: yes, 2005
The influence of selected control strategies on the level of low-order current harmonic distortion generated by an inverter connected to a distorted grid is investigated through a combination of theoretical and experimental studies.
Abeyasekera, T.   +3 more
core   +2 more sources

An Improved Current Control Strategy for a Grid-Connected Inverter under Distorted Grid Conditions

open access: yesEnergies, 2016
This paper presents an improved current control strategy for a three-phase grid-connected inverter under distorted grid conditions. The main challenge associated with the grid-connected inverter in distributed generation (DG) systems is to maintain the ...
Ngoc Bao Lai, Kyeong-Hwa Kim
doaj   +1 more source

Low order harmonic cancellation in a grid connected multiple inverter system via current control parameter randomization [PDF]

open access: yes, 2005
In grid connected multiple inverter systems, it is normal to synchronize the output current of each inverter to the common network voltage. Any current controller deficiencies, which result in low order harmonics, are also synchronized to the common ...
Abeyasekera, T.D.   +3 more
core   +1 more source

MULTILEVEL INVERTER BASED GRID CONNECTED STATCOM

open access: yesInternational Journal of Electronics and Electical Engineering, 2015
Modern day power systems, power electronic devices are playing vital role in every aspect of the power system network. Among various devices multi-level inverters are the most efficient devices due to their Simple circuit configuration, reliability and cost effective implementation.
POCHANAPEDDI MYTHILI, GRANDHI RAMU
openaire   +1 more source

Improved droop control strategy for grid-connected inverters [PDF]

open access: yesSustainable Energy, Grids and Networks, 2015
An improved control strategy for grid-connected inverters within microgrids is presented in this paper. The strategy is based on the classical P-ω and Q-V droop method. The improvement in the proposed control strategy is twofold: Firstly, the transient response of the droop controller is improved by replacing the traditional method of measuring average
Abusara, M. A.   +2 more
openaire   +4 more sources

An improved method of phase-locked loop grid-connected inverter based on capacitor voltage full feedforward

open access: yesEnergy Reports, 2022
Different from the conventional grid voltage feedforward, the capacitive voltage type full feedforward will not amplify high frequency harmonics, and it can eliminate the capacitor current control and simplify the controller design.
Ying Li   +4 more
doaj   +1 more source

A Deadbeat Grid一connected Control Strategy of the Single Phase Z/Q一Z Source Inverter

open access: yesJournal of Harbin University of Science and Technology, 2017
In order to improve the efficiency of Z/Q-Z source inverter and output current quality,reduce the harmonic distortion rate of grid-connected current,the control strategy of grid-connected current is applied to the Z/Q-Z source inverter.
YAN JLUg-bin   +4 more
doaj   +1 more source

Passivity Enhancement Strategy of Grid-Connected Inverter System Based on the Adaptive Active Damper

open access: yesFrontiers in Energy Research, 2022
The grid-connected inverter system may be unstable when connected to a weak grid, and installing an active damper as a virtual resistor at the PCC is convenient for stabilizing the system.
Chen Shi, Jianfeng Zhao
doaj   +1 more source

Harmonics and THD analysis of Five phase inverter drive with Single tuned filter using Simulink/MATLAB [PDF]

open access: yes, 2017
This paper aims at the reduction of harmonics in Five phase inverter drive using Single tuned filter. This filter eliminates most of the harmonic content at the output AC voltage/current before connecting to any load or grid. Inverter designs performance
Ananda, A.S., Manjesh, .
core   +1 more source

Development of 10 kW Three-Phase Grid Connected Inverter [PDF]

open access: yesAutomatika ‒ Journal for Control, Measurement, Electronics, Computing and Communications, 2016
In this paper, modeling, simulation and experimental study of a 10 kW three-phase grid connected inverter are presented. The mathematical model of the system is derived, and characteristic curves of the system are obtained in MATLAB with m-file for various switching frequencies, dc-link voltages and filter inductance values.
Isen, Evren, Bakan, A. Faruk
openaire   +4 more sources