Results 71 to 80 of about 53,814 (292)
When the Grid-Following (GFL) and the Grid-Forming (GFM) converters are hybrid-connected to the grid, they are coupled through the grid impedance. During grid faults, the transient characteristics of the two converters become more complex due to this ...
Baoyu Zhai +5 more
doaj +1 more source
Stabilization of L‐PBF Ni50.7Ti49.3 under low‐cycle loading was investigated. Recoverable strain after cycling was dependent on the amount of applied load. Recovery ratio was 53.4% and 35.1% at intermediate and high load, respectively. The maximum total strain reached 10.3% at a high load of 1200 MPa.
Ondřej Červinek +5 more
wiley +1 more source
Power control strategies during voltage sags according to Spanish grid code [PDF]
In order to connect any power converters into the grid there are some grid requirements to insure the safe operation of the grid. So, the control of the converters especially during abnormal condition e.g. during voltage sags is
Bakkar, Mostafa +4 more
core +1 more source
Creep experiments at 900°C on coarse‐grained steel‐ceramic composites containing recycled magnesia reveal that higher ceramic volume fractions significantly enhance the creep resistance. Detailed EBSD investigations identify subgrain formation in the steel matrix as the dominant deformation mechanism.
Moritz Müller +6 more
wiley +1 more source
Demonstration of sustained and useful converter responses during balanced and unbalanced faults in microgrids [PDF]
In large power grids where converter penetration is presently low and the network impedance is predominantly reactive, the required response from converters during faults is presently specified by phrases such as “maximum reactive output”.
Burt, Graeme +4 more
core +1 more source
Four‐point bending tests are conducted in an argon atmosphere on commercial MgO‐C brick grades with and without MgO‐C recyclate from room temperature up to 1300 °C. No detrimental effect of the MgO‐C recyclates on bending strength is found. Instead, a decisive influence of the total carbon content is observed, with lower total carbon contents ...
Alexander Schramm +5 more
wiley +1 more source
Grid Forming Converters for Low Inertia Systems
The rapid integration of renewable energy sources into the power grid has resulted in the high utilization of power-electronics devices and operating power systems where inverter-based resources are dominated.
Qusay Salem +3 more
doaj +1 more source
An adaptive disturbance rejection control scheme for voltage regulation in DC micro-grids [PDF]
© 2019 IEEE. Personal use of this material is permitted. Permission from IEEE must be obtained for all other uses, in any current or future media, including reprinting/republishing this material for advertising or promotional purposes, creating new ...
Costa Castelló, Ramon +2 more
core +1 more source
Assessing Altered Coating Adhesion on Plasma‐Deoxidized Surfaces Under Oxygen‐Free Conditions
This study demonstrates the effectiveness of atmospheric pressure plasma pretreatment in modifying silicon and stainless steel surfaces to improve adhesion. Argon‐hydrogen plasma increases surface roughness and improves adhesion strength, whereas pure argon results in smoother surfaces and structural changes.
Selina Raumel +6 more
wiley +1 more source
Bioinspired Shape‐Memory Hook Fasteners With Programmable Interlocking and Silent Release
Bioinspired hook fasteners made from epoxy shape‐memory polymers are shown to switch between strong, secure attachment and gentle, silent release when heated. By combining programmable geometry and material response, these adaptive fasteners outperform commercial systems in strength and noise control, enabling new solutions for robotics, medical ...
Maria I. Vallejo Ciro +3 more
wiley +1 more source

