Results 51 to 60 of about 21,060 (306)

Limits, stability and disturbance rejection analysis of voltage control loop strategies for grid forming converters in DC and AC microgrids with high penetration of constant power loads [PDF]

open access: yes, 2017
This paper extensively analyzes the operation limits, system stability and disturbance rejection capability of the voltage control loops used in master-slave AC and DC Microgrids (MGs).
Cano, J.M.   +3 more
core   +2 more sources

A light‐triggered Time‐Resolved X‐ray Solution Scattering (TR‐XSS) workflow with application to protein conformational dynamics

open access: yesFEBS Open Bio, EarlyView.
Time‐resolved X‐ray solution scattering captures how proteins change shape in real time under near‐native conditions. This article presents a practical workflow for light‐triggered TR‐XSS experiments, from data collection to structural refinement. Using a calcium‐transporting membrane protein as an example, the approach can be broadly applied to study ...
Fatemeh Sabzian‐Molaei   +3 more
wiley   +1 more source

Small signal modeling and stability analysis of multi-VSCs for grid-forming converters under low impedance grid

open access: yes电力工程技术
The grid-forming converter has voltage source characteristics,providing damping and frequency support to high-impedance weak grids,and demonstrates good stability. However,instability may occur under low impedance grids.
Yongkang CHEN   +5 more
doaj   +1 more source

Grid‐forming requirements based on stability assessment for 100% converter‐based Irish power system

open access: yesIET Renewable Power Generation, 2022
The fault response of a 100% converter‐based system can be significantly different to that of a synchronous generator‐based system, considering the lower capacity headroom, but flexible control capability, of power electronic converters.
Xianxian Zhao   +2 more
doaj   +1 more source

ROCOV scheme for Fault Detection and Location in HVDC sytems [PDF]

open access: yes, 2019
A reliable DC fault protection system is essential for the development of HVDC grids. Therefore, this paper deals with the voltage derivative ROCOV scheme to locate and detect DC faults.
Abarrategi, O.   +4 more
core   +2 more sources

Predicting Epileptogenic Tubers in Patients With Tuberous Sclerosis Complex Using a Fusion Model Integrating Lesion Network Mapping and Machine Learning

open access: yesAnnals of Clinical and Translational Neurology, EarlyView.
ABSTRACT Objective Accurate localization of epileptogenic tubers (ETs) in patients with tuberous sclerosis complex (TSC) is essential but challenging, as these tubers lack distinct pathological or genetic markers to differentiate them from other cortical tubers.
Tinghong Liu   +11 more
wiley   +1 more source

Influence of Load Dynamics on Converter-Dominated Isolated Power Systems

open access: yesApplied Sciences, 2021
The operation of isolated power systems with 100% converter-based generation requires the integration of battery energy storage systems (BESS) using grid-forming-type power converters.
José Gouveia   +2 more
doaj   +1 more source

On the robustness of ultra-high voltage 4H-SiC IGBTs with an optimized retrograde p-well [PDF]

open access: yes, 2019
The robustness of ultra-high voltage (>10kV) SiC IGBTs comprising of an optimized retrograde p-well is investigated. Under extensive TCAD simulations, we show that in addition to offering a robust control on threshold voltage and eliminating punch ...
Antoniou, M.   +5 more
core   +1 more source

ALDOA Promotes Glycolysis and NLRP3/GSDMD Pyroptosis to Accelerate ALS Progression

open access: yesAnnals of Clinical and Translational Neurology, EarlyView.
ABSTRACT Objective Amyotrophic lateral sclerosis (ALS) is characterized by progressive motor neuron degeneration. Glycolytic dysregulation is implicated in disease progression, yet the underlying mechanisms remain unclear. This study investigates how Aldolase A (ALDOA) drives ALS progression through glycolysis‐mediated motor neuron pyroptosis.
Kaixin Yan   +9 more
wiley   +1 more source

A novel fault analysis method considering control states for MMC grid-forming system with renewable energy generation

open access: yesInternational Journal of Electrical Power & Energy Systems
This paper analyzes the fault equivalent models of grid-following and grid-forming converters under various fault conditions. A novel fault calculation method for MMC-HVDC grid-forming systems integrated with 100% renewable energy generation is proposed.
Bohao Zhou   +5 more
doaj   +1 more source

Home - About - Disclaimer - Privacy