Results 91 to 100 of about 44,267 (264)
On-line 2 to 150 kHz grid impedance meter
Active In-feed Converters (AIC) generate harmonics with frequencies up to 100 kHz resulting in power losses over the distribution lines, transformers and consumer loads, and interferences with control signals.
Merendaz, Lionel +2 more
core +1 more source
A novel thermos‐responsive hydroxypropyl cellulose/graphene oxide (HPC/GO) composite membrane is fabricated for reversible temperature‐gated ion transport in aqueous zinc‐ion batteries. Enabled by LCST‐driven structural transition, unimpeded ion diffusion at room temperature delivers high capacity, while elevated temperature suppresses transport; full ...
Xueli Bi +9 more
wiley +1 more source
Given the problems that the phase-locked loop frequency coupling effect (PLL-FCE) in a weak grid reduces the quality of the output current waveform and brings challenges to maintaining a steady running of the grid-connected converter (GCC), this paper ...
Ye Zhang, Haibo Pen, Xiaoyu Zhang
doaj +1 more source
GeodiseLab: making the grid usable
The GeodiseLab project is supported by the OMII managed programme to extend and improve the Geodise toolboxes which provide Grid client functionality to Problem Solving Environments (PSEs) used by engineers and scientists.
Molinari, Marc +4 more
core
Our study demonstrates Brønsted base‐mediated proton transfer for HOAc dissociation regulation in weakly acidic electrolytes, where imidazole achieves optimal dynamic proton equilibrium‐simultaneously stabilizing Zn anodes and enabling efficient Mn2+/MnO2 conversion.
Wenli Xin +7 more
wiley +1 more source
When grid side converter (GSC) is connected to weak grid, the small signal instability can happen due to terminal characteristics of the GSC that are incompatible with the grid impedance.
Liang Chen, Heng Nian, Yunyang Xu
doaj +1 more source
Impedance-based Stability Assessment of Self-Synchronising Power Electronics Converter
Self-synchronization, which is an unconventional control framework for grid-tied power electronics converters (PECs), uses the internal signals of current regulators instead of direct measurement of ac grid voltages, to obtain ac grid phase information ...
Donald Grahame Holmes (18043990) +6 more
core
Self‐Healing and Stretchable Synaptic Transistor
A self‐healing stretchable synaptic transistor (3S‐T) is realized using a p‐PVDF‐HFP‐DBP/PDMS‐MPU‐IU bilayer as gate insulator, where dipole‐dipole interaction enhances polarization to achieve a large memory window. Leveraging its neuronal biomimicry, the synaptic transistor demonstrates electrically compatibility with the biological brain. Furthermore,
Hyongsuk Choo +10 more
wiley +1 more source
Sub-Synchronous Oscillation Suppression Based on VSG Virtual Impedance Feasible Domains
[Objective] The virtual synchronous generator (VSG) system exhibits negative damping characteristics under weak grid connection, which triggers subsynchronous oscillations and leads to system instability.
Yuxin SUN, Qin SUN, Yi DU
doaj +1 more source
Solvent Co‐Intercalation Enabled Ca Storage in MoS2 for Ca‐Ion Batteries
Regulating electrolyte solvation levels enables otherwise non‐intercalatable Ca2+ ions to reversibly co‐intercalate into molybdenum disulfide (MoS2) as ether‐solvated species. The intercalation reversibility is strongly governed by solvent chain length, as demonstrated using diethylene glycol dimethyl ether (G2) and tetraethylene glycol dimethyl ether (
Yudong Luo +10 more
wiley +1 more source