Results 141 to 150 of about 8,474 (251)
Nondestructive Testing of Welded Composite Metal Foams
X‐ray computed tomography (CT) is used to evaluate welded steel–steel composite metal foam (CMF) joints of two density classes. It reports variation in postweld spatial void distribution and correlates it to weld‐induced changes, mechanical performance, and failure within welded CMF panels.
Chinmaya Prerana Inguva +2 more
wiley +1 more source
A distinct semi‐confined inner‐tube chemical vapor deposition geometry enables reproducible, large‐area growth of phase‐pure 2D β′‐In2Se3 from InI + Se precursors. Engineering local vapor transport and optimizing precursor delivery and temperature–time conditions yield uniform continuous films.
Dasun P. W. Guruge +8 more
wiley +1 more source
The Effect of Force, Frequency and Gripping on Muscle Activity during a cyclic Push Task
Risk factors for the development of upper extremity work-related musculoskeletal disorders (UE WMSD) include high repetition, high force, and the combination of high force and high repetition (Moore et al.
Brown, Melissa M.
core
Composite Ti–6Al–4V–epoxy lattice structures are additively manufactured and epoxy infiltrated for cyclic loading. At low lattice volume fractions, hybridization produces synergistic gains in stiffness and energy dissipation. At higher volume fractions, synergy diminishes, although composites still exceed metallic lattices in specific energy ...
Joey Tallon +3 more
wiley +1 more source
SOFTWARE-HARDWARE SYSTEM FOR CONTROLLING THE PRESSURE APPLIED BY THE GRIPPING DEVICE TO THE OBJECT
Background. Modern prostheses equipped with feedback do not fully allow control over the pressure applied to an object. This study is aimed at developing a control system that enables the regulation of the pressure applied, thereby enhancing the ...
N.A. Burimsky +2 more
doaj +1 more source
From Shear to Sound: Mechanics–Acoustics Mapping of TPMS Lattices
Triply periodic minimal surface (TPMS) lattices are mapped across mechanical and acoustic performance, revealing that descriptors validated in compression fail under shear. First‐time comparison with trusses included. A transition from porous to resonance‐driven absorption emerges at 25% density.
Lucía Doyle +3 more
wiley +1 more source
Characterization of Dynamic Gripping Force Feedback for Robot-Assisted Surgery
Haptic feedback of gripping forces during robotassisted surgery can benefit the surgical outcome by means of reduced forces applied to the tissue. A custom-designed haptic user interface allows to control four degrees of freedom of the instrument’s ...
Schäfer Max B. +7 more
core +1 more source
This review highlights advances in lightweight, lead‐free polymer nanocomposites for diagnostic X‐ray shielding. By linking filler chemistry, dispersion, architecture, and photon interaction mechanisms, it establishes structure–performance relationships guiding material design.
Aklilu G. Messele +2 more
wiley +1 more source
The purpose of this investigation was to compare the maximal dominant hand grip strength and the perceived grip force used while gripping a tennis racket of female college students with varying tennis backgrounds.
Bean, Ann Sastri
core
Influence of Geometric Design on Mechanical Performance of Auxetic Metastructure
Strategic geometric reinforcement transforms auxetic performance. This study evaluates 3D‐printed arrowhead metastructures, revealing that a modified design with local ring reinforcement suppresses premature failure to achieve superior energy absorption and structural efficiency.
Muhammad Gulzari +3 more
wiley +1 more source

