Thanks to the open publication in recent years, the general public can now view and evaluate ground motion data. However, the data offered in web portals are often only optimized for display, and there is no automatic detection of hotspots and their ...
Michael Rudolf+4 more
doaj +1 more source
Using deep learning generated CBCT contours for online dose assessment of prostate SABR treatments
Abstract Prostate Stereotactic Ablative Body Radiotherapy (SABR) is an ultra‐hypofractionated treatment where small setup errors can lead to higher doses to organs at risk (OARs). Although bowel and bladder preparation protocols reduce inter‐fraction variability, inconsistent patient adherence still results in OAR variability.
Conor Sinclair Smith+8 more
wiley +1 more source
JACMP – Founding and 2000–2004
Journal of Applied Clinical Medical Physics, EarlyView.
Michael Mills
wiley +1 more source
Accounting for TLD response to CBCT protocols in external beam radiotherapy dose monitoring
Abstract Purpose LiF thermoluminescent dosimeters (TLDs) are commonly used in radiation therapy to verify the delivered dose. Examples include dose verification for complicated treatment setups or cardiovascular implantable electronic devices (CIEDs). TLDs may be present for both the pre‐treatment imaging kilovoltage (kV) beam and the megavoltage (MV ...
Andrew J. White+5 more
wiley +1 more source
Hybrid predictor for ground-motion intensity with machine learning and conventional ground motion prediction equation. [PDF]
Kubo H+4 more
europepmc +1 more source
Recorded Versus Synthetic Ground Motions: A Comparative Analysis of Structural Seismic Responses [PDF]
This paper presents a comparative analysis of structural seismic responses under two types of ground motion inputs: (i) synthetic motions generated by stochastic ground motion models and (ii) recorded motions from an earthquake database. Five key seismic response metrics - probability distributions, statistical moments, correlations, tail indices, and ...
arxiv
Abstract The establishment of guidelines and curriculum standards for medical physics residency training is a critical component of setting expectations and competencies for the profession. Since the last publication of these standards, residency training has become integrated into the eligibility criteria for most medical physics certification bodies.
Jonathon A. Nye+16 more
wiley +1 more source
Abstract Purpose Sparing pharyngeal constrictor muscles (PCMs) during radiotherapy improves patient‐reported swallowing function. This study aimed to explore the feasibility of integrating knowledge‐based planning (KBP) with multicriteria optimization (MCO) in Eclipse v18.0 to selectively spare PCM, quantify the required trade‐off in prophylactic ...
Laura K. Howard+3 more
wiley +1 more source
Impact of respiratory motion on dose distribution in SIB‐SBRT for lung cancer
Abstract Purpose Respiratory motion is a major source of dose uncertainty in lung cancer radiotherapy. The dose distribution of simultaneous integrated boost‐stereotactic body radiotherapy (SIB‐SBRT) is inhomogeneous and is significantly impacted by respiratory motion for lung cancer. The effect of respiratory motion on SIB‐SBRT was investigated with a
Lingling Liu+7 more
wiley +1 more source
Seismological Processing of Six Degree-of-Freedom Ground-Motion Data. [PDF]
Sollberger D+9 more
europepmc +1 more source