Results 21 to 30 of about 5,952 (245)

Principle of Flexible Ground-Fault Arc Suppression Device Based on Zero-Sequence Voltage Regulation

open access: yesIEEE Access, 2021
Single-line-to-ground (SLG) fault arcs cause the intermittent over-voltages, leading to short circuits within large-scale area. In this paper, a flexible arc suppression device is proposed, which adopts a zigzag grounding transformer, multi-terminal ...
Bishuang Fan   +6 more
doaj   +1 more source

A Non-Destructive Testing Method for Fault Detection of Substation Grounding Grids

open access: yesSensors, 2019
The grounding grid is critical to the safety and stability of a power system. Corrosive cracking of the grounding conductor is the main cause of deterioration of grounding grid performance. Existing fault diagnosis methods for grounding grids are limited
Xiujuan Wang   +4 more
doaj   +1 more source

A TECHNIQUE OF MEASURING OF RESISTANCE OF A GROUNDING DEVICE

open access: yesElectrical engineering & Electromechanics, 2016
Introduction. Measurement of resistance of the grounding device (GD) by means of a three-electrode system. This requires not only the right choice of installation locations of measuring electrodes, but also the determination of the point of zero ...
I.V. Nizhevskyi, V.I. Nizhevskyi
doaj   +1 more source

Developing evidence‐based, cost‐effective P4 cancer medicine for driving innovation in prevention, therapeutics, patient care and reducing healthcare inequalities

open access: yesMolecular Oncology, EarlyView.
The cancer problem is increasing globally with projections up to the year 2050 showing unfavourable outcomes in terms of incidence and cancer‐related deaths. The main challenges are prevention, improved therapeutics resulting in increased cure rates and enhanced health‐related quality of life.
Ulrik Ringborg   +43 more
wiley   +1 more source

Ground water level monitoring device on marshland [PDF]

open access: yesThe 9th International Conference "Environmental Engineering 2014", 2014
This paper presents the overall concept of a design of a multi-sensor water level measurement device. Requirements, possible applications and design schemes are presented and described. Some basic considerations on the possible equipment, electronic parts and algorithms are also included.
Jacek Rapinski   +2 more
openaire   +1 more source

Tracking Motor Progression and Device‐Aided Therapy Eligibility in Parkinson's Disease

open access: yesAnnals of Clinical and Translational Neurology, EarlyView.
ABSTRACT Objective To characterise the progression of motor symptoms and identify eligibility for device‐aided therapies in Parkinson's disease, using both the 5‐2‐1 criteria and a refined clinical definition, while examining differences across genetic subgroups.
David Ledingham   +7 more
wiley   +1 more source

Multi-point synchronous temporary grounding wire detection device based on convolutional neural networks

open access: yesInternational Journal of Electrical Power & Energy Systems
To prevent grounding accidents caused by forgetting to remove the temporary grounding wires and the contact of trees with the distribution network, a multi-point synchronous temporary grounding wire detection device based on convolutional neural networks
Linfei Yin, Yuhan Li
doaj   +1 more source

Lessons Learned From a Delayed‐Start Trial of Modafinil for Freezing of Gait in Parkinson's Disease

open access: yesAnnals of Clinical and Translational Neurology, EarlyView.
ABSTRACT Objective Freezing of gait (FOG) in people with Parkinson's disease (PwPD) is debilitating and has limited treatments. Modafinil modulates beta/gamma band activity in the pedunculopontine nucleus (PPN), like PPN deep brain stimulation. We therefore tested the hypothesis that Modafinil would improve FOG in PwPD.
Tuhin Virmani   +8 more
wiley   +1 more source

A Method of Applying Mixtures to Optimize Grounding during Installation of Vertical Composite Grounding Devices

open access: yesИзвестия высших учебных заведений и энергетических объединенний СНГ: Энергетика
The article considers the method of using mixtures to optimize the electrophysical  parameters of grounding devices in conjunction with vertical composite grounding conductors.  It has been found that fluctuations in soil resistivity caused by changes in
I. A. Pavlovich   +3 more
doaj   +1 more source

Ensuring the reliability of energy systems through the application of a new method for introducing soil-replacement mixtures during the installation of deep grounding devices [PDF]

open access: yesE3S Web of Conferences
This paper discusses a method for using mixtures to optimize the electrical parameters of grounding devices during the installation of vertical composite ground electrodes.
Pavlovich Ivan   +3 more
doaj   +1 more source