Results 61 to 70 of about 1,663,340 (286)
ABSTRACT Chitosan, a polysaccharide upcycled from biowaste, has long promised sustainable, biocompatible, and antimicrobial films and devices, an appeal reinforced by its recent regulatory recognition, with several chitosan‐based antibacterial dressings gaining clearance through the Food and Drug Administration's 510(k) pathway.
Jacopo Nicoletti +16 more
wiley +1 more source
Introduction. Earthing device electrical substation in modern conditions must meet both the requirements of electrical safety of people and animals, as well as electromagnetic compatibility requirements established her electrical equipment.
V. I. Nizhevskyi +3 more
doaj
ObjectiveDuring the operation of metro vehicles,influenced by factors such as wheel-rail impact vibration and the internal structure of the axle-end grounding device itself,the carbon brush cables within the axle-end grounding devices are prone to ...
Xiaofeng ZHANG, Songsong XIAO
doaj +1 more source
Purpose. The creation of a measuring device for determining the impedance of the grounding of lightning arresters and supports of overhead lines under the influence of aperiodic pulses with the parameters 1.2/50 μs, 8/20 μs and 10/350 μs.
D. G. Koliushko +3 more
doaj +1 more source
Optoelectronic synaptic devices based on solution‐processed molecular telluride GST‐225 phase‐change inks are demonstrated for three‐factor learning. A global optical signal broadcast through a silicon waveguide induces non‐volatile conductance updates exclusively in locally electrically flagged memristors.
Kevin Portner +14 more
wiley +1 more source
Grounding at source transformers or generators in a distribution system can help to stabilise system voltages and enhance overall reliability and safety.
Liao Rih-Neng, Chen Tsai Hsiang
core
Helix grounding electrode with good grounding performance [PDF]
Grounding electrode is used for discharging current and ensure the safe and stable operation of electrical equipment. Grounding performance of grounding electrode will degradation with limited installation space.
Zhanlong Zhang +4 more
core +3 more sources
Research on Suspended Monorail Traction Power Return Grounding Fault Detection Protection Mechanism
The traction power return grounding fault of suspended monorail in station will lead to large-scale tripping of circuit breakers of other trains and adjacent traction substations.
ZHANG Kun +3 more
doaj
At present the devices that use the pulse method to measure the resistance of a grounding device (GD) of the 110 kV overhead power line (OHL) supports have the following disadvantage: to do the measurements, various circuits must be assembled.
M.V. Borodin +4 more
doaj +1 more source
Ferroelectric tunnel junction devices based on epitaxial undoped ferroelectric HfO2 films demonstrate stable switching endurance of over 106 switching cycles, low write voltages of ±3 V, 16 measured resistance states, and neuromorphic capability.
Markus Hellenbrand +13 more
wiley +1 more source

