Results 81 to 90 of about 8,720 (263)

Theoretical Study and Resistance Reduction Performance of a Pipeline-Type Grounding Grid in Seepage-Proof Pumped Storage Power Stations

open access: yesEnergies
Pumped storage power stations commonly adopt impermeable linings at reservoir bottoms to reduce seepage losses. However, these linings significantly weaken the current dissipation capability of grounding grids, particularly in high-resistivity bedrock ...
Wanqin Ding   +5 more
doaj   +1 more source

Adaptive Foam 3D Printing of Ultralight and Multifunctional Materials

open access: yesAdvanced Engineering Materials, EarlyView.
Adaptive foam 3D printing, enabled by expandable microspheres, imparts cellular structures to thermoplastic and thermosetting polymers, manufactured through a variety of processes including fused filament fabrication, direct ink writing, digital light processing, and inkjet printing.
Nariman Rajabifar, Amir Ameli
wiley   +1 more source

1-ohm Impedance Criterion for Diagnosis of Single-Phase Ground Fault of Transmission Line

open access: yesIEEE Access
The transition resistance during single-phase grounding faults in transmission lines is closely related to the fault cause. Quickly determining the cause of the fault through the transition resistance value and taking targeted measures to restore the ...
Xueming Zhou   +6 more
doaj   +1 more source

Non‐Additive Criteria Assessment in Sustainability Evaluation of High Entropy Alloys: A Toxicity‐Weighted Framework

open access: yesAdvanced Engineering Materials, EarlyView.
Sustainability assessment requires methodologies that appropriately distinguish between additive and non‐additive material properties. A toxicity‐weighted scoring system is developed and applied that accounts for the disproportionate influence of highly toxic constituents through nonlinear weighting functions, providing more realistic estimates than ...
Seth Mehalic   +2 more
wiley   +1 more source

Feasibility Analysis of Application of HX Series Electric Locomotive Under Ground Fault Mode

open access: yes机车电传动, 2021
Three grounding fault detection schemes of HX series electric locomotives were introduced, and it was evaluated whether there were potential electrical safety hazards when single point grounding occured in different grounding ranges under different ...
Yanmin ZHANG   +5 more
doaj  

Simulation‐Based Analysis of Insert Pull‐Out in Nickel‐Polyurethane Hybrid Foams Using CT‐Derived Geometries

open access: yesAdvanced Engineering Materials, EarlyView.
CT‐based finite element simulations combined with in situ X‐ray computed tomography are used to analyze insert pull‐out in nickel‐coated polymer foams. Despite variations in material parameters, deformation consistently concentrates within a narrow annular region around the insert.
Yannik Bautz   +4 more
wiley   +1 more source

A fault line selection method for flexible grounding systems based on zero-sequence current phase variation

open access: yesZhejiang dianli
To address the poor tolerance to transitional resistance and incomplete utilization of fault information in grounding protection for flexible grounding systems, a fault line selection method based on current phase variation is proposed.
LI Zong   +5 more
doaj   +1 more source

Fabrication Routes for Ionic Conducting Fiber Strain Sensors

open access: yesAdvanced Engineering Materials, EarlyView.
Ionic conducting fiber strain sensors (ICFSs) offer compliant, textile‐integrable sensing. Thus far, the commercialization of ICFSs has been constrained by fiber fabrication routes. This review provides a fabrication‐centric analysis of ICFSs correlating processing strategies with material properties and scalability.
Leo John Kershaw   +3 more
wiley   +1 more source

A Simple Procedure to Obtain the Grounding Resistance Measurement of Very Large and Urban Electrodes by a Modified Fall-of-Potential Method

open access: yesApplied Sciences
The measurement of the grounding resistance of grounding grids in large installations as well as grounding electrodes in urban areas is addressed in this article. The resistance value is obtained using a three-pin array by measuring the fall-of-potential
Jorge Moreno   +5 more
doaj   +1 more source

Home - About - Disclaimer - Privacy