1-ohm Impedance Criterion for Diagnosis of Single-Phase Ground Fault of Transmission Line
The transition resistance during single-phase grounding faults in transmission lines is closely related to the fault cause. Quickly determining the cause of the fault through the transition resistance value and taking targeted measures to restore the ...
Xueming Zhou +6 more
doaj +1 more source
Feasibility Analysis of Application of HX Series Electric Locomotive Under Ground Fault Mode
Three grounding fault detection schemes of HX series electric locomotives were introduced, and it was evaluated whether there were potential electrical safety hazards when single point grounding occured in different grounding ranges under different ...
Yanmin ZHANG +5 more
doaj
Estimation of an Upper Bound to the Value of the Step Potentials in Two-Layered Soils from Grounding Resistance Measurements. [PDF]
Moreno J +4 more
europepmc +1 more source
Solvate ionic liquids lubrication reduced the coefficient of friction by ∼60% compared to dry sliding, reaching steady‐state values as low as 0.04–0.05. Corrosion weight‐loss measurements in 1 M HCl further demonstrated significant inhibition behavior, with only 100 ppm of [Li(G3)][TFSI] (∼68.5 μL/L) reducing corrosion‐product weight loss by 63 ...
Sameh Dabees +6 more
wiley +1 more source
Geometrical modifications on nitrocellulose membranes can result in observable differences in signal intensity relative to a reference membrane (top and bottom left). Using two reference experiments, we have developed a theoretical model that can reproduce the experimentally observed flow changes and provide information on membrane parameters, e.g ...
Maria Dimaki +2 more
wiley +1 more source
To address the poor tolerance to transitional resistance and incomplete utilization of fault information in grounding protection for flexible grounding systems, a fault line selection method based on current phase variation is proposed.
LI Zong +5 more
doaj +1 more source
Architecture‐Driven Sensor Stability in Weft‐Knitted Engineering Textiles
Textile‐integrated sensor architectures are systematically compared to evaluate their electromechanical behavior under combined mechanical and environmental loading. Pocket‐based integration exhibits stable and reproducible signals, whereas tunnel‐based routing shows higher sensitivity accompanied by increased variability.
Adnan Maroof Khan +5 more
wiley +1 more source
The measurement of the grounding resistance of grounding grids in large installations as well as grounding electrodes in urban areas is addressed in this article. The resistance value is obtained using a three-pin array by measuring the fall-of-potential
Jorge Moreno +5 more
doaj +1 more source
The through-flow experiment in the simulated state of earth fault of various alloy materials were done, the variable parameters of resistivity were obtained.
Heng Ling Yang +4 more
core +1 more source