DETERMINATION OF THE MUTUAL GROUND RESISTANCE OF ADJACENT GROUNDING GRIDS
U članku je obrađena problematika određivanja međusobnog otpora uzemljenja dvaju bliskih, metalno povezanih, uzemljivača. S tom svrhom izveden je izvorni analitički izraz za izračunavanje odgovarajućeg međusobnog otpora uzemljenja među bliskim ...
Sarajčev, Petar +2 more
core
Enhanced Strength and Corrosion Resistance of Ti‐13Nb‐12Ta‐10Zr‐4Sn Alloy by Aging Treatment
This work systematically investigates the effect of aging treatment on mechanical properties and corrosion behavior of vacuum arc‐melted Ti‐13Nb‐12Ta‐10Zr‐4Sn alloy. Owing to the increased α″ martensite, strength and corrosion resistance were significantly enhanced by aging treatment.
Yuhua Li +5 more
wiley +1 more source
Pumped storage power stations commonly adopt impermeable linings at reservoir bottoms to reduce seepage losses. However, these linings significantly weaken the current dissipation capability of grounding grids, particularly in high-resistivity bedrock ...
Wanqin Ding +5 more
doaj +1 more source
Ensuring the reliability of energy systems through the application of a new method for introducing soil-replacement mixtures during the installation of deep grounding devices [PDF]
This paper discusses a method for using mixtures to optimize the electrical parameters of grounding devices during the installation of vertical composite ground electrodes.
Pavlovich Ivan +3 more
doaj +1 more source
Analisa Penggunaan NGR (Neutral Grounding Resistance) pada Transformator 150/20 kV dan 70/20 kV di Gardu Induk Skyline. [PDF]
Pada Gardu Induk Skyline terdapat 4 transformator yang menggunakan pentanahan secara Neutral Grounding Resistance (NGR) dan pentanahan secara langsung ( Solid Grounding ).
Sole, Vetly Tandi
core
This plot compares experimental tensile stress–strain curves (with 4 different strain rates) and corresponding modelled curves (obtained using the optimised sets of Voce and Miller–Norton parameter values shown). The inferred M‐N values, characterizing the creep, are very similar to those obtained via conventional creep testing.
S. Ooi, R. P. Thompson, T. W. Clyne
wiley +1 more source
THE EXPERIMENTAL VALIDATION OF THE GROUNDING DEVICE RESISTANCE MEASUREMENT METHOD
Purpose. The paper considers experimental research of three-electrode units for measuring the resistance of grounding devices for different purposes. Methodology. The experimental study of the method of resistance measurement of grounding devices for any
Nizhevskyi, I. V. +5 more
core +3 more sources
1-ohm Impedance Criterion for Diagnosis of Single-Phase Ground Fault of Transmission Line
The transition resistance during single-phase grounding faults in transmission lines is closely related to the fault cause. Quickly determining the cause of the fault through the transition resistance value and taking targeted measures to restore the ...
Xueming Zhou +6 more
doaj +1 more source
Feasibility Analysis of Application of HX Series Electric Locomotive Under Ground Fault Mode
Three grounding fault detection schemes of HX series electric locomotives were introduced, and it was evaluated whether there were potential electrical safety hazards when single point grounding occured in different grounding ranges under different ...
Yanmin ZHANG +5 more
doaj
Graphene nanoplatelet (0.1 wt.%) reinforcement significantly enhances the performance of β Ti‐28Nb‐35.4Zr alloy. Grain refinement, reduced water contact angle, and improved surface characteristics promote osteoblast adhesion and complete surface coverage after 7 days.
Khurram Munir +5 more
wiley +1 more source