A Synchronous Variable-Stroke Mechanism for Workspace Enhancement of a Four-Finger Soft Robotic Hand. [PDF]
Chen H, Wang Z, Zhang S, Yao L.
europepmc +1 more source
Experimental Study of Cold‐Formed Steel Floor Joists under Serviceability Limit State
Abstract Cold‐formed steel (CFS) floor joists are increasingly utilised in mid‐rise building construction owing to their high strength‐to‐weight ratio, fabrication efficiency, and ease of installation. These floor joists are typically configured as truss systems with top and bottom chords fabricated from unlipped channels, and diagonal web channels ...
Ruilin Zhang +4 more
wiley +1 more source
Numerical Simulation of the Effect of Process Parameters on Pass Filling Degree in F-Section Steel Finishing Rolling Process. [PDF]
Duan H +5 more
europepmc +1 more source
On the Shear Force Capacity of Sinusoidal Corrugated Web Girders
Abstract According to EN 1993‐1‐5:2024, the shear resistance of plate girders with flat webs is determined by considering the contribution of both the web and a defined portion of the flanges. However, in the design of corrugated web beams the flange contribution is neglected, leading to a fundamental difference in the assessment of shear capacity.
Gábor Hajdú +2 more
wiley +1 more source
Comparison of flange creation in three-piece intraocular lenses between high- and low-temperature cautery. [PDF]
Kronschläger M +5 more
europepmc +1 more source
Web crippling performance of perforated Modular Construction Optimised beams under ITF loading.
Abstract The growing use of modular construction has increased demand for lightweight high‐strength cold‐formed steel (CFS) beams capable of carrying concentrated loads efficiently. Modular Construction Optimised (MCO) beams have been developed to meet this need; however, in practice they often incorporate web openings to accommodate services.
Jack Lifsey +6 more
wiley +1 more source
Unifying energy and information harvesting for high-rate self-powered sensing. [PDF]
Yu H +10 more
europepmc +1 more source
Contact Force Distribution Between CLT‐Slab And Steel Beam In Slim‐Floor Construction
Abstract In slim‐floor beam–column systems, the distribution of contact forces between cross‐laminated timber (CLT) slabs and steel beams is critical for structural design. Existing guidelines are largely based on concrete floors, although CLT slabs exhibit different structural behavior due to their bidirectional bending stiffness.
Rishwa Colombage +4 more
wiley +1 more source
Assessment of Flexible Dosing Volumes in an Existing Spring-Driven Autoinjector Platform. [PDF]
Derakhshandeh R +3 more
europepmc +1 more source
Digital geometry capture and stability‐based reuse classification of structural steel
Abstract This paper presents an integrated visual, geometric, and mechanical assessment framework in which reuse potential is governed by measured geometry. Reclaimed steel profiles from a demolition project were assessed through visual inspection, manual measurement, high‐resolution 3D scanning, and tensile and compression testing.
Niamh Gallagher +4 more
wiley +1 more source

