Results 71 to 80 of about 1,671,228 (249)

An Investigation of Quality of Life of Head-and-neck Cancer Patients after Tumor Resection and Subsequent Prosthetic Rehabilitation: A Clinical Study

open access: yesJournal of International Clinical Dental Research Organization
Background: Head-and-neck cancer and its treatment can decrease the quality of life (QoL) of patients in consequence of the loss of structural and functional integrity of the oro- and nasopharyngeal region.
Saee Deshpande, Usha Radke, Neelam Pande
doaj   +1 more source

A Paradigm for the Analysis of Preloaded Bolted Joints

open access: yesJournal of Mechanical Engineering, 2019
The purpose of this paper is to present a paradigm, or guide, to the analysis of preloaded bolted joints made using multiple bolts. Classical analysis methods are applied to the interaction of the joint elements subjected to combinations of both in-plane
Welch Michael
doaj   +1 more source

Mitigating Train Derailments Due to Sharp Curve and Overspeed

open access: yesFrontiers in Mechanical Engineering, 2018
Each year around the world there are still several cases of train derailments on the curved tracks due to overspeed, leading to big casualties and costs to the rail industries.
Yan Q. Sun
doaj   +1 more source

Fastened Aluminum-Lipped Channel Sections Subjected to Web Crippling under Two-Flange Loading Conditions:Experimental Study [PDF]

open access: yes, 2020
Thin-walled members in structural systems are highly vulnerable to buckling instabilities, including web crippling. Aluminum alloy members are more prone to this kind of failure due to their relatively low elastic moduli.
Guan, Hong   +6 more
core   +1 more source

Optical Multiphase Conductivity Inline Probe: Characterization and Analysis of Foam Structures

open access: yesChemie Ingenieur Technik, EarlyView.
A novel inline probe combines optical imaging and electrical conductivity within a shared measurement volume, enabling simultaneous determination of foam structure and composition. The method provides real‐time access to cell size distributions and liquid fractions under process conditions. ABSTRACT For inline process analysis of foams, a novel optical
Marc Hofmann   +3 more
wiley   +1 more source

Total removal of the buccal flange in maxillary prosthetic preparation: a necessity?: case report

open access: yesRGO: Revista Gaúcha de Odontologia
Fixed implant-supported complete maxillary dentures aim to rehabilitate aesthetic, phonetic, and functional aspects of edentulous arches. A previous prosthetic preparation without a flange in the anterior sector makes it possible to evaluate the labial ...
Stephanie Gomes Assunção Alves   +4 more
doaj   +1 more source

Integral Experiments and Magnetic Resonance Imaging of Lab‐Scale Liquid Distributors

open access: yesChemie Ingenieur Technik, EarlyView.
Four lab‐scale liquid distributors were evaluated based on the homogeneity of the resulting liquid distribution. The best‐performing design reduced maldistribution and wall flow compared to a single‐point liquid distribution and remained stable under varying operating conditions, including different gas and liquid loads.
Hannah S. Rennebaum   +4 more
wiley   +1 more source

Fabrication of cast metal guidance flange prosthesis for a patient with segmental mandibulectomy: A clinical report

open access: yesJournal of Craniomaxillofacial Research, 2015
Introduction: Mandibular resection usually results in altered mandibular movements, disfigurement,and difficulty in swallowing, impaired speech/articulation and deviation of the mandible toward theresected site.
Foad Akhoondinasab   +4 more
doaj  

Four-piece CAD-CAM surgical guide for computer-guided surgery of immediate complete denture and implant-retained overdenture

open access: yesDigital Dentistry Journal
Objective: To describe a digital workflow incorporating computer-aided design and computer-aided manufacturing (CAD-CAM) surgical guides and dynamic computer-assisted implant surgery (CAIS) for implant planning and placement in a mandibular immediate ...
Duangporn Yongyosrungrueng   +3 more
doaj   +1 more source

Iron shield boss with copper-alloy ?plated flange rivets

open access: yes, 2021
Iron shield-boss: diam. 17.8cm, height 7.5cm. A broad, low, boss with convex dome and spike surmounted by a button (broken), marked carination at sides above an indented waist and a broad flange 2.5cm wide.
Helena Hamerow (11585575)
core   +1 more source

Home - About - Disclaimer - Privacy