Results 91 to 100 of about 860 (135)
H62 Palliative care in advanced Huntington’s disease: a scoping review
Dorine Boersema-Wijma +2 more
openalex +2 more sources
Some of the next articles are maybe not open access.
Related searches:
Related searches:
Surface Topography Metrology and Properties, 2022
In order to improve the corrosion resistance of brass treated by plasma electrolytic oxidation (PEO), Na2WO4 additive was introduced into a mixed electrolyte of sodium silicate and sodium hydroxide, and a composite oxide coating was formed on the surface
Qi-Man Guan +6 more
semanticscholar +1 more source
In order to improve the corrosion resistance of brass treated by plasma electrolytic oxidation (PEO), Na2WO4 additive was introduced into a mixed electrolyte of sodium silicate and sodium hydroxide, and a composite oxide coating was formed on the surface
Qi-Man Guan +6 more
semanticscholar +1 more source
Ferroelectrics (Print), 2022
Graphene oxide particles (GOp) were implanted on the surface of H62 copper alloy by friction stir surface processing (FSSP) to obtain a H62/GOp modified layer.
W. Song +4 more
semanticscholar +1 more source
Graphene oxide particles (GOp) were implanted on the surface of H62 copper alloy by friction stir surface processing (FSSP) to obtain a H62/GOp modified layer.
W. Song +4 more
semanticscholar +1 more source
Journal of tribology, 2021
The cylinder block/valve plate interface in the axial piston pump has been proven to be easily worn out, which will increase power loss and reduce its efficiency. The valve plate surface is required to be manufactured with low viscous friction and wear.
Luanxia Chen +3 more
semanticscholar +1 more source
The cylinder block/valve plate interface in the axial piston pump has been proven to be easily worn out, which will increase power loss and reduce its efficiency. The valve plate surface is required to be manufactured with low viscous friction and wear.
Luanxia Chen +3 more
semanticscholar +1 more source
Cytometry. Part B, Clinical cytometry
The Clinical and Laboratory Standards Institute (CLSI) H62—Validation of Assays Performed by Flow Cytometry guideline, released in 2021, provides recommendations for platform workflow and quality system essentials, instrument setup and standardization ...
S. A. Monaghan +19 more
semanticscholar +1 more source
The Clinical and Laboratory Standards Institute (CLSI) H62—Validation of Assays Performed by Flow Cytometry guideline, released in 2021, provides recommendations for platform workflow and quality system essentials, instrument setup and standardization ...
S. A. Monaghan +19 more
semanticscholar +1 more source
Experimental Study on Fretting Wear Behaviors of H62 Brass under Prestressed Conditions
Tribology TransactionsThe fretting wear behavior of H62 brass against GCr15 steel under prestressed conditions was studied using a self-developed fretting wear device in this study.
Xin Liu, Jing Zhang, Peng Sui
semanticscholar +1 more source
Surface review and letters, 2020
By utilizing the ABAQUS software, this paper simulates and analyzes the forming of the H62 foil subjected to multi-pulse laser dynamic forming (LDF).
J. Geng +4 more
semanticscholar +1 more source
By utilizing the ABAQUS software, this paper simulates and analyzes the forming of the H62 foil subjected to multi-pulse laser dynamic forming (LDF).
J. Geng +4 more
semanticscholar +1 more source
Effect of passive film on the galvanic corrosion of titanium alloy Ti60 coupled to copper alloy H62
Materials and Corrosion, 2019Ti alloys exhibit high potential because of the compact passive film. However, the effect of passive film on galvanic corrosion is not clear. On the one hand, the great potential difference can accelerate the galvanic corrosion of other metals with low ...
Pingping Zhao +4 more
semanticscholar +1 more source
Atmospheric corrosion of T2 copper and H62 brass exposed in an urban environment
Materials Chemistry and Physics, 2023Xuankai Wang +6 more
semanticscholar +1 more source

