Comparação entre métodos de medição da camada semi-redutora em radiologia
The Half Value Layer (HVL) is a parameter used in Quality Control (QC), to evaluate the X-ray beam quality. The HVL can be measured through the X-ray primary beam attenuation measurement using knew thickness slabs of 99% purity aluminum (M1) or by ...
Denyel Jefferson Prado Faria +4 more
doaj +1 more source
Gamma Ray and FTIR Studies in Zinc Doped Lead Borate Glasses for Radiation Shielding Application [PDF]
Gamma ray shielding properties of borate glass samples containing oxides of lead and zinc are prepared by melt and quench technique and evaluated theoretically using XCOM computer software for gamma ray shielding properties.
Zakiyyu Ibrahim Takai +8 more
doaj +1 more source
Impacts of micro-size PbO on the gamma-ray shielding performance of polyepoxide resin
A series of polyepoxide resins doped by lead oxide with low concentrations were fabricated in order to study the impacts of low PbO concentrations on the fabricated composites’ physical- and radiation-shielding properties.
Alorain Dalal A. +3 more
doaj +1 more source
In this study, we developed flexible composites using silicone rubber (SR) or polydimethylsiloxane as the matrix and WO3 and BaO nanoparticles as filler to analyze their radiation-shielding performance. The linear attenuation coefficient (LAC) values for
Alorain Dalal A. +3 more
doaj +1 more source
Measurement of Half-value Layer in Mammography
The half-value layer (HVL) of an X-ray beam for film-screen mammography is considered an important parameter for image quality and patient dose. Thus, HVL must be measured in accordance with The Manual of Accuracy for Mammography printed by the Japanese Society of Radiological Technology.
Hirofumi, Yagi +4 more
openaire +3 more sources
Radiation shielding potential of ultra-high strength concrete from agro-industrial waste [PDF]
Ultra-high strength concrete produced with agro-residual wastes and industrial by-products were tested for radiation shielding capacity by measuring the linear attenuation coefficient, half value layer and tenth value layer.
Rajkumar Deivendiran +2 more
doaj +1 more source
The Precision of Half-value Layer Measurement on Mammography
The half-value layer (HVL) is an important index of the image quality or radiation risk in mammography. Radiation risk of the breast tissue is evaluated with the average glandular dose. The HVL index is indispensable for the average glandular dose computations.
Ishii, Rie +4 more
openaire +3 more sources
Determining X-Ray Effective Energy in Linear Accelerator (LINAC) Radiotherapy Instrument
This research in determining x-ray effective energy in linear accelerator (Linac) radiotherapy device was done using copper plates at different thicknesses by determining the Half Value Layer (HVL) for each energy. The purpose of this research is to know
Fauziah Fauziah, Bualkar Abdullah
doaj +1 more source
Method for Shielding Evaluation of Industrial Radiography with Ir [PDF]
Background Iridium-192 (192Ir) is one of the radioisotopes most commonly utilized for industrial radiography worldwide. In accordance with the Nuclear Safety Act of the Republic of Korea, the use of projectors containing 192Ir sources requires conducting
Byeonghyeon Park +3 more
doaj +1 more source
This study aimed to determine the contribution of B2O3/CdO substitution on gamma-ray attenuation behaviors of 46V2O5–46P2O5–(8−x)B2O3–xCdO (x = 0–8 mol%) glass system.
H.O. Tekin +8 more
doaj +1 more source