Results 41 to 50 of about 5,508 (296)

Harmonic mitigation in wind power plants : Active filter solutions [PDF]

open access: yes, 2016
Passive solutions are the most used harmonic mitigation methods in wind power plants, but the use of active filters is also a suitable and attractive approach.
Schwanz, Daphne,   +3 more
core   +1 more source

Mitigation of voltage and current harmonics in grid-connected microgrids [PDF]

open access: yes2012 IEEE International Symposium on Industrial Electronics, 2012
In this paper, a control approach is proposed for selective compensation of main voltage and current harmonics in grid-connected microgrids. Two modes of compensation are considered, i.e. voltage and current compensation modes. In the case that sensitive loads are connected to the point of commoncoupling (PCC), voltage compensation mode is activated in
Mehdi Savaghebi   +3 more
openaire   +2 more sources

Mitigation of harmonics in a 6 kV and 650 kW motor

open access: yesElectrical Engineering, 2023
Motors that work with high voltage and consume a lot of power, specifically those of 6 kV and 650 kW, generate harmonics of voltage and current harmful to the electro-energy system, causing problems in its correct operation. In this study, the quality of the electrical energy of a motor having those characteristics is analyzed by measuring voltage ...
Corrales Barrios, Luis B.   +4 more
openaire   +3 more sources

MITIGATION OF HARMONICS IN INVERTER

open access: yesIOSR Journal of Engineering, 2012
In recent years power electronic converters are widely used in industrial as well as domestic applications for the control of power flow for automation and energy efficiency.Most of the time these converters draw harmonic current and reactive power from AC source and causes the power quality problems. Recently multilevel power conversion technology has
openaire   +1 more source

An optimum reactance one-port compensator for harmonic mitigation [PDF]

open access: yes, 2005
The installation of electronic devices, digital equipment, and nonlinear loads in both industrial and domestic applications have dramatically increased in recent years, which in turn increased the level of harmonics in the system.
E.F. El-Saadany   +3 more
core   +1 more source

Integrating Voltage-Source Active Filters into Diode Front-End Rectifiers – Harmonic Mitigation and Power Factor Correction [PDF]

open access: yes, 2021
The ongoing grid integration of power electronic based loads requires the increasing use of power filters in order to maintain a high power quality and stability.
Bernet, Daniel, Hiller, Marc
core   +2 more sources

Linear quadratic regulator-based coordinated optimization for harmonic compensation in multifunctional grid-connected inverters

open access: yesInternational Journal of Electrical Power & Energy Systems
The increasing penetration of distributed energy resources (DERs) and electric vehicles (EVs) introduces widespread power electronic devices that significantly challenge harmonic mitigation in distribution systems.
Xianghua Peng   +6 more
doaj   +1 more source

Reducing Harmonic Voltage At Industrial Area Distribution Network Using Network Configuration Management [TK1007. S526 2008 f rb]. [PDF]

open access: yes, 2008
Syarikat pembekal elektrik diperlukan untuk mengekalkan tahap voltan harmonik di dalam sistem di bawah batas piawaian. Electric utility company is required to maintain harmonic voltage level in the system below the standard’s ...
Latif, Mohd Shahed
core  

European Standard Clinical Practice Guideline and EXPeRT Recommendations for the Diagnosis and Management of Gastroenteropancreatic Neuroendocrine Neoplasms in Children and Adolescents

open access: yesPediatric Blood &Cancer, EarlyView.
ABSTRACT Pediatric gastroenteropancreatic neuroendocrine neoplasms (GEP‐NENs) are extremely rare and clinically heterogeneous. Management has largely been extrapolated from adult practice. This European Standard Clinical Practice Guideline (ESCP), developed by the EXPeRT network in collaboration with adult NEN experts, provides (adult) evidence ...
Michaela Kuhlen   +23 more
wiley   +1 more source

Improving the performance of UPQC under unbalanced and distortional load conditions: A new control method [PDF]

open access: yesJournal of Artificial Intelligence and Data Mining, 2015
This paper presents a new control method for a three-phase four-wire Unified Power Quality Conditioner (UPQC) to deal with the problems of power quality under distortional and unbalanced load conditions.
R. Ghanizadeh, M. Ebadian
doaj   +1 more source

Home - About - Disclaimer - Privacy