Results 101 to 110 of about 49,590 (306)
Hemodynamics of a Bileaflet Mechanical Heart Valve with Different Levels of Dysfunction [PDF]
Heart disease is one of leading causes of mortality worldwide. Healthy heart valves are key for proper heart function. When these valves dysfunction, a replacement is often necessary in severe cases. The current study presents an investigation of the pulsatile blood flow through a bileaflet mechanical heart valve (BMHV) where one leaflet is healthy and
arxiv +1 more source
Clinical results with the 31 mm CoreValve™ in large aortic annuli: The importance of implantation technique [PDF]
The CoreValve Revalving System (CRS) (Medtronic Inc., Minneapolis, MN, USA) is currently available in four sizes: 23 mm, 26 mm, 29 mm and 31 mm.
Cammalleri, V+9 more
core +1 more source
ABSTRACT Background Paravalvular regurgitation (PVR) following transcatheter aortic valve replacement (TAVR) is a complication linked to poor outcomes. The prognostic impact of mild PVR, particularly in patients with elevated preprocedural left ventricular (LV) filling pressure, remains uncertain.
Shumpei Kosugi+12 more
wiley +1 more source
Detecting total hip replacement prosthesis design on preoperative radiographs using deep convolutional neural network [PDF]
Identifying the design of a failed implant is a key step in preoperative planning of revision total joint arthroplasty. Manual identification of the implant design from radiographic images is time consuming and prone to error. Failure to identify the implant design preoperatively can lead to increased operating room time, more complex surgery ...
arxiv +1 more source
Two-Stream Regression Network for Dental Implant Position Prediction [PDF]
In implant prosthesis treatment, the design of the surgical guide heavily relies on the manual location of the implant position, which is subjective and prone to doctor's experiences. When deep learning based methods has started to be applied to address this problem, the space between teeth are various and some of them might present similar texture ...
arxiv
AIMS Multiple surgical revisions are often necessary in individuals with congenital heart defects affecting the RVOT or pulmonary valve. There are no multicentre data on the feasibility and safety of percutaneous pulmonary valve implantation (PPVI) using
A. Lehner+12 more
semanticscholar +1 more source
Restoration of a Stuck Leaflet
ABSTRACT Severe aortic regurgitation (AR) for a leaflet malfunction after transcatheter aortic valve implantation (TAVI) is a dreadful complication that can lead even to cardiogenic shock. New valve's design has reduced the rate of paravalvular regurgitation, however central regurgitation is still a challenging complication.
Elisa Tomarelli+3 more
wiley +1 more source
Objective: The aim of this retrospective study was to compare early postoperative outcomes after aortic valve replacement (AVR) with sutureless bioprostheses and conventional stented bioprostheses implanted through median sternotomy.
Syed Saleem Mujtaba+5 more
doaj +1 more source
Surgical Bailout Therapy after Implantation of a Medtronic CoreValve Bioprosthesis
Moderate-to-severe paraprosthesic leak causing hemodynamic deterioration and left ventricular remodeling can occur after transcatheter aortic valve implantation (TAVI).
Rita Calé+7 more
doaj +1 more source
Prediction of Turbulent Shear Stresses through Dysfunctional Bileaflet Mechanical Heart Valves using Computational Fluid Dynamics [PDF]
There are more than 300,000 heart valves implanted annually worldwide with about 50% of them being mechanical valves. The heart valve replacement is often a common treatment for severe valvular disease. However, valves may dysfunction leading to adverse hemodynamic conditions.
arxiv