Transapical aortic valve implantation with a self-expanding anatomically oriented valve [PDF]
Aims The Medtronic Engager™ aortic valve bioprosthesis is a self-expanding valve with support arms facilitating anatomically correct positioning and axial fixation. Valve leaflets, made of bovine pericardium, are mounted on a Nitinol frame.
Aicher, Diana +8 more
core
Cost-utility of transcatheter aortic valve implantation for inoperable patients with severe aortic stenosis treated by medical management: a UK cost-utility analysis based on patient-level data from the ADVANCE study. [PDF]
OBJECTIVE: To use patient-level data from the ADVANCE study to evaluate the cost-effectiveness of transcatheter aortic valve implantation (TAVI) compared to medical management (MM) in patients with severe aortic stenosis from the perspective of the UK ...
Bleiziffer, S +13 more
core +1 more source
Abstract Soft robots, engineered from highly compliant materials, offer superior adaptability and safety in unstructured environments compared to their rigid counterparts. Recent advancements, fueled by bio‐inspiration and material programmability, have led to the rapid co‐evolution of their core modules: actuation, sensing, protection, energy, and ...
Qiulei Liu +3 more
wiley +1 more source
Two-year outcomes after transcatheter or surgical aortic-valve replacement. [PDF]
BACKGROUND: The Placement of Aortic Transcatheter Valves (PARTNER) trial showed that among high-risk patients with aortic stenosis, the 1-year survival rates are similar with transcatheter aortic-valve replacement (TAVR) and surgical replacement. However,
Akin, Jodi J +24 more
core +1 more source
Mono‐ and bivalent‐, alanine‐modified poly‐iso‐butylenes, folding into beta‐sheets, were prepared by living carbocationic polymerization and subsequent endgroup modification. These PIB‐conjugates are useful as solid polymers for the drug release of triamcinolone and nimodipine. ABSTRACT Poly‐iso‐butylene (PIB) is a well known biocompatible polymer with
Philipp S. Hilgeroth +2 more
wiley +1 more source
Prognostic value of the ratio between prothesis area and indexed annulus area measured by multiSlice-CT for transcatheter aortic valve implantation procedures [PDF]
Background Postprocedural aortic regurgitations following transcatheter aortic valve implantation (TAVI) procedures remain an is- sue. Benefit of oversizing strategies to prevent them isn’t well established.
Bical A +8 more
core
The Application of Telemedicine in Surgery
This figure provides an overview of the content presented in this article. Telemedicine is integrated throughout the entire surgical workflow, with distinct applications across the preoperative, intraoperative, and postoperative phases. These applications are enabled by a suite of supporting technologies, while the associated implementation challenges ...
Yufan Yang +8 more
wiley +1 more source
Surgical Bailout Therapy after Implantation of a Medtronic CoreValve Bioprosthesis
Moderate-to-severe paraprosthesic leak causing hemodynamic deterioration and left ventricular remodeling can occur after transcatheter aortic valve implantation (TAVI).
Rita Calé +7 more
doaj +1 more source
TCT-117 Quality of Life Outcomes Among High-Risk Patients Undergoing TAVR via the Transapical Approach: A PARTNER Continued Access Substudy [PDF]
El fin de este artículo es realizar una comparación entre dos técnicas empleadas para la Resolución de Ambigüedades basándose en su expresión matemática más simple y en su aplicación a las medidas ...
Kirtane, Ajay J. +15 more
core +1 more source
Guidelines for Essential Trauma Care: Second Edition (2026)
Injury is a major cause of death and disability globally, with the highest burden in low‐ and middle‐income countries (LMICs). Strengthening the organization and planning for trauma care (care of the injured) can improve care and lower mortality. In 2004, the International Association for Trauma Surgery and Intensive Care (IATSIC) and the World Health ...
Charles Mock +41 more
wiley +1 more source

