Uncoupling of the Helical Blade in a Proximal Femoral Nail - A Novel Mechanical Failure. [PDF]

open access: yesJ Orthop Case Rep
Bhakhar A   +5 more
europepmc   +1 more source

Neural Fields for Highly Accelerated 2D Cine Phase Contrast MRI

open access: yesAdvanced Science, EarlyView.
ABSTRACT 2D cine phase contrast (CPC) MRI provides quantitative information on blood velocity and flow within the human vasculature. However, data acquisition is time‐consuming, motivating the reconstruction of the velocity field from undersampled measurements to reduce scan times. In this work, neural fields are proposed as a continuous spatiotemporal
Pablo Arratia   +7 more
wiley   +1 more source

Adverse Hemodynamics in Kommerell's Diverticulum: A Comparative Case Report Linking Oscillatory Shear Index to Aortic Dissection. [PDF]

open access: yesClin Case Rep
Sakakibara K   +14 more
europepmc   +1 more source

Splenic artery fenestration - a previously undescribed arterial variant. [PDF]

open access: yesSurg Radiol Anat
Triantafyllou G   +5 more
europepmc   +1 more source

Influence of scan mode, tilt, and radiation dose on CT radiomic metrics. [PDF]

open access: yesJ Appl Clin Med Phys
Yadav N   +5 more
europepmc   +1 more source

A calf with concurrent infantile hemangioma and coronary artery fistula: notes on simultaneous onset. [PDF]

open access: yesJ Vet Med Sci
Kawada Y   +9 more
europepmc   +1 more source

High temporal resolution for multislice helical computed tomography

Medical Physics, 2000
Multislice helical computed tomography (CT) substantially reduces scanning time. However, the temporal resolution of individual images is still insufficient for imaging rapidly moving organs such as the heart and adjacent pulmonary vessels. It may, in some cases, be worse than with current single‐slice helical CT.
Katsuyuki Taguchi, Hirofumi Anno
exaly   +3 more sources

Synchronized Multi-Helical Computed Tomography

2021 2nd International Conference on Control, Robotics and Intelligent System, 2021
Limited by the field of view (FOV), most existed X-ray industrial computed tomography (ICT) techniques require multi scans for stitching projections when detecting long objects, which significantly increases the scanning time. In addition, these techniques usually adopt the one-by-one scanning mode that further reduces the scanning efficiency ...
Changsheng Zhang 0006   +2 more
openaire   +1 more source