Results 51 to 60 of about 1,024 (133)

HIFU: therapeutische Ultraschallanwendung

open access: yesSwiss Medical Forum ‒ Schweizerisches Medizin-Forum, 2018
Ultraschallwellen konnen in gebundelter und hochintensiver Form zu therapeutischen Zwecken eingesetzt werden.
Aurélien Dupré, David Melodelima
openaire   +1 more source

Strategic Design of Soft Actuators in Translational Medical Robotics for Human‐Centered Healthcare

open access: yesAdvanced Robotics Research, Volume 2, Issue 5, October 2026.
Soft robotics enables biocompatible, compliant medical devices, but clinical translation requires design‐driven engineering beyond materials. This perspective reviews implantable, surgical, and wearable systems by actuation mechanism, highlighting how optimized architectures and integration improve mechanical interfacing, adaptability, and durability ...
Ho Jun Jin   +3 more
wiley   +1 more source

Comparative Analysis of Clinical Efficacy of High-Intensity Focused Ultrasound Ablation and Radiofrequency Ablation in Patients with Benign Breast Tumors

open access: yesTechnology in Cancer Research & Treatment
Introduction: This study compared the efficacy, complications, and related indicators of High-Intensity Focused Ultrasound Ablation (HIFU) and Radiofrequency Ablation (RFA) for treating benign breast tumors, aiming to provide effective evidence-based ...
Zhiyong Liu MD   +2 more
doaj   +1 more source

Histological characterization of HIFU lesions

open access: yesInternational Journal of Hyperthermia
Background: High intensity focused ultrasound (HIFU) can destroy tissue by thermal ablation which may be accompanied by acoustic cavitation and/or tissue water boiling, but the biological and histological effects of these treatments have not been fully documented. Here, detailed histological analysis over time using well characterized HIFU exposures in
Ian Rivens   +3 more
openaire   +3 more sources

Immediate intraoperative detrusor muscle status at primary transurethral resection of bladder tumour: a prospective, blinded, paired cohort, feasibility study using fluorescence confocal microscopy (IB1‐LaserComplete study)

open access: yesBJU International, Volume 138, Issue 4, Page 705-713, October 2026.
Objectives To evaluate ex vivo fluorescence confocal microscopy (FCM) for immediate detrusor muscle (DM) assessment during primary transurethral resection of bladder tumour (TURBT). Patients and Methods This prospective, blinded, paired‐cohort feasibility study enrolled consecutive patients undergoing primary TURBT for suspected non‐muscle‐invasive ...
Martin J. Connor   +20 more
wiley   +1 more source

Development of temperature controller-integrated portable HIFU driver for thermal coagulation

open access: yesBioMedical Engineering OnLine, 2019
Background Temperature monitoring during high-intensity focused ultrasound (HIFU) therapy on tissue is essential to regulate the degree of thermal coagulation and to achieve the desired treatment outcomes eventually.
Suhyun Park   +3 more
doaj   +1 more source

The effect of ultrasound-guided high-intensity focused ultrasound treatment for cesarean scar pregnancy on ovarian reserve

open access: yesInternational Journal of Hyperthermia, 2021
Objective The aim of this study was to evaluate changes in anti-Müllerian hormone (AMH) levels after ultrasound-guided high-intensity focused ultrasound (USgHIFU) treatment of cesarean scar pregnancy (CSP).
Wenping Wang   +5 more
doaj   +1 more source

HIFU for Palliative Treatment of Pancreatic Cancer

open access: yes, 2016
Pancreatic cancer is one of the deadliest malignancies, with only a 6 % 5-year survival rate and over 50 % of patients being diagnosed at the advanced stage. Current therapies are ineffective, and the treatment of patients with advanced disease is palliative.
Tatiana D, Khokhlova, Joo Ha, Hwang
openaire   +3 more sources

Multi‐Parametric Biophysical Analysis for Evaluating Suitability of Energy‐Based Devices and Injectables

open access: yesJournal of Cosmetic Dermatology, Volume 25, Issue 10, October 2026.
ABSTRACT Background The paradigm of cosmetic dermatology has shifted heavily toward combination therapies involving energy‐based devices (EBDs) and injectable biostimulators. However, conventional efficacy assessments remain largely limited to subjective clinical grading or single‐parameter, uni‐dimensional approaches.
Jin Ho Kim   +3 more
wiley   +1 more source

Efficacy and Safety of 1.5‐ and 3.0‐mm High‐Intensity Focused Ultrasound for Eyebrow Lifting in Korean Adults: A Prospective Randomized Split‐Face Study

open access: yesSkin Research and Technology, Volume 32, Issue 10, October 2026.
ABSTRACT Background High‐intensity focused ultrasound (HIFU) is widely used for noninvasive eyebrow lifting, but within‐subject comparisons of cartridge focal depths are scarce. Objective To evaluate the efficacy and safety of 1.5‐ and 3.0‐mm cartridges for eyebrow lifting in Korean adults, with an exploratory between‐depth comparison.
Kwang Ho Yoo, Hyewon Song, Yuhwa Choi
wiley   +1 more source

Home - About - Disclaimer - Privacy