Results 11 to 20 of about 978,622 (297)
The neutral point of the distribution network is grounded with low resistance, which can quickly remove single‐phase grounding fault and effectively suppress overvoltage. However, the existing zero‐sequence overcurrent protection has a high setting value.
Gang Wang, Liyi Wang
doaj +3 more sources
Fault Location of Generator Stator with Single-Phase High-Resistance Grounding Fault Based on Signal Injection. [PDF]
This paper proposes a novel method for locating single-phase grounding faults in generator stator windings with high resistance, which are typically challenging to locate due to weak fault characteristics.
Lei B +7 more
europepmc +2 more sources
The paper focuses on single-neutral-point low-resistance grounding (SNP-LRG) active distribution networks (ADNs) where the distribution system adopts the low-resistance grounding mode, and distributed generation (DG) grid-connected transformers adopt the
Jing Zhang +3 more
doaj +2 more sources
A Capacitance-to-Ground Measuring Method for Medium-Voltage Power Grid of a Ship Based on the Combination of High and Low Frequencies [PDF]
With the increase in capacity of large ship electric power systems, medium-voltage electric power systems have gradually become an inevitable choice. Among China’s large ships, the neutral point of the power system is usually grounded by high resistance,
Shuai Wang +3 more
doaj +2 more sources
To address challenges in locating high-impedance grounding faults (HIGFs) and isolating fault areas in resonant grounding systems, this paper proposes a novel fault identification method based on coordinating a Peterson coil and a resistance grounding ...
Zhengyang Li +4 more
doaj +2 more sources
Application of Low Voltage High Resistance Grounding in Nuclear Power Plants
Most nuclear power plants now utilize solid grounded low voltage systems. For safety and reliability reasons, the low voltage (LV) high resistance grounding (HRG) system is also increasingly used in the pulp and paper, petroleum and chemical, and ...
Choong-Koo Chang +1 more
doaj +2 more sources
Simulation and Experiment Analysis of 10 kV Flexible Grounding Device
The traditional 10 kV distribution network grounding system has some disadvantages, such as small grounding current and poor arc extinguishing effect, thus, hindering the detection of high-resistance grounding fault.
Mengxuan Liu, Chi Zhang, Kangli Liu
doaj +1 more source
The resistance temperature characteristics and thermal stability of graphite based flexible grounding materials were studied. With the method of current heating and constant temperature protection, the resistance of grounding body at each temperature was
HU Songjiang +6 more
doaj +1 more source
Potentials' distribution in high resistivity soil around extended grounding electrodes [PDF]
The potential distribution in high resistivity soil around extended grounding electrodes has been described in the paper. The high-voltage polygon has been developed for experimental investigation.
Ivonin V. V.
doaj +1 more source
In view of problems of limited terrain, short effective dispersion length, and low resistance reduction efficiency in the extensional resistance reduction of the grounding grid of incoming line section of mine substation, a resistance reduction method ...
XIE Hongping +5 more
doaj +1 more source