Results 1 to 10 of about 45,196 (330)
Arcing High Impedance Fault Detection Using Real Coded Genetic Algorithm
Safety and reliability are two of the most important aspects of electric power supply systems. Sensitivity and robustness to detect and isolate faults can influence the safety and reliability of such systems.
Al-Othman, A.K. +2 more
core
Enhanced independent pole control of hybrid MMC-HVDC system [PDF]
This paper presents an enhanced independent pole control scheme for hybrid modular multilevel converter (MMC) based on full bridge sub-module (FBSM) and half bridge sub-module (HBSM). A detailed analysis of power distribution between upper and lower arms
Ling, Weixing +3 more
core +1 more source
The design of high-performance grounding systems is a cornerstone of safety and reliability in modern AC substations, particularly under increasingly severe fault and transient operating conditions.
Mahmoud Wahba +3 more
doaj +1 more source
Power line fault detection based on waveform comparison offline location technology
This study proposes a distribution line fault detection and location technology based on waveform comparison, aiming to improve fault detection accuracy and shorten analysis time.
Li Shengzhu +4 more
doaj +1 more source
Line selection method for mine small-current grounding based on optimized VMD and RF
In underground small-current grounding power supply systems, the decomposition performance of the single-phase grounding fault line selection method based on Variational Mode Decomposition (VMD) depends heavily on the selection of parameters such as the ...
ZHU Jun +5 more
doaj +1 more source
BEHAVIOUR OF BACKFILL MATERIALS FOR ELECTRICAL GROUNDING SYSTEMS UNDER HIGH VOLTAGE CONDITIONS [PDF]
Backfill materials like Bentonite and cement are effective in lowering grounding resistance of electrodes for a considerable period. During lightning, switching impulses and earth fault occurrences in medium and high voltage networks, the grounding ...
S. C. LIM +4 more
doaj
Analisa Gangguan Satu Fasa Ke Tanah Yang Mengakibatkan Sympathetic Trip Pada Penyulang Yang Tidak Terganggu Di PLN APJ Surabaya Selatan [PDF]
Twenty kilovolts power distribution network system at East Java use high resistance (500 ?) grounding system that makes maximum single phase to ground fault current 25 Amperes. To detect this fault current, a Directional Ground Relay (DGR) is used.
Kongdoro, R. (Rusli) +2 more
core
Fault current characterisation in VSC-based HVDC systems [PDF]
The DC-side line faults in high-voltage direct-current (HVDC) systems utilising voltage-source converters (VSCs) are a major concern for multi-terminal HVDC systems in which complete isolation of the faulted system is not a viable option.
Ademi, Sul +4 more
core +1 more source
When a single-phase ground (SPG) fault occurs in a non-effectively grounding system (NUGS), it is crucial to locate the fault section quickly. However, existing detection methods for high-resistance grounding faults suffer from low locating accuracy, and
Xinhui Zhang +4 more
doaj +1 more source
How to protect a wind turbine from lightning [PDF]
Techniques for reducing the chances of lightning damage to wind turbines are discussed. The methods of providing a ground for a lightning strike are discussed.
Dodd, C. W. +2 more
core +1 more source

