A new method for single‐phase high resistance grounding fault protection in low resistance grounded distribution networks

open access: yesEngineering Reports, 2023
AbstractThe neutral point of the distribution network is grounded with low resistance, which can quickly remove single‐phase grounding fault and effectively suppress overvoltage. However, the existing zero‐sequence overcurrent protection has a high setting value.
Gang Wang, Liyi Wang
openaire   +3 more sources

High Resistance Grounding Fault Perception and Identification Method in Asymmetric Distribution Network

open access: yesZhongguo dianli
Aiming at the problems of fault perception and identification in high resistance grounding fault of distribution network, a high resistance grounding fault perception method for parameter-asymmetric distribution network based on damping rate variation is proposed.
Penghui YANG   +5 more
openaire   +3 more sources

Calculation of two-phase ground fault current with consideration of equipment grounding specifications [PDF]

open access: yes, 2018
The article describes ways of calculating two-phase ground fault current in electrical networks with isolated neutral for needs of calculating thermal resistance in equipment\u27s grounding elements.
Aleksandr Suhoguzow   +5 more
core   +2 more sources

Simulation and Experiment Analysis of 10 kV Flexible Grounding Device

open access: yes, 2021
The traditional 10 kV distribution network grounding system has some disadvantages, such as small grounding current and poor arc extinguishing effect, thus, hindering the detection of high-resistance grounding fault.
Chi Zhang, Mengxuan Liu, Kangli Liu
core   +1 more source

Analysis of energy dissipation in resistive superconducting fault-current limiters for optimal power system performance [PDF]

open access: yes, 2011
Fault levels in electrical distribution systems are rising due to the increasing presence of distributed generation, and this rising trend is expected to continue in the future.
Burt, Graeme   +4 more
core   +3 more sources

Installation of high resistance grounding system on the ungrounded system at offshore platform [PDF]

open access: yes, 2021
Single line to earth fault usually can be seen in the ungrounded system. The ungrounded system is used widely in offshore platforms due to its advantages over the overvoltage whenever a fault occurs in the power systems.
Nader Nassif Barsoum   +4 more
core   +1 more source

Ground distance relaying algorithm for high resistance fault

open access: yesIET Generation, Transmission & Distribution, 2010
This study proposes a new fault impedance estimation algorithm of phase-ground fault for ground distance relaying based on the negative-, zero- and comprehensive negative-zero-sequence current component. The principle is based on the assumption that fault path is purely resistive, and the phase angle of fault point voltage and fault path current is ...
Z.Y. Xu, S.J. Jiang, Q.X. Yang, T.S. Bi
openaire   +1 more source

Grounding Fault Model of Low Voltage Direct Current Supply and Utilization System for Analyzing the System Grounding Fault Characteristics

open access: yes, 2021
Grounding fault analysis is of vital importance for low voltage direct current (LVDC) supply and utilization systems. However, the existing DC grounding fault model is inappropriate for LVDC supply and utilization system.
Kaiqi Sun   +4 more
core   +1 more source

Fault Protection Based on the Ratio of Zero-sequence Current Projection Components for Low-resistance Grounding System

open access: yes, 2021
The electrical characteristics of a single-phase grounding fault in a low-resistance grounding system was aualyzed, and a fault protection scheme was proposed for low-resistance grounding systems according to the ratio of the zero-sequence current ...
Wenping QIN   +4 more
core   +1 more source

From junk to function — How weak selection in eukaryotes builds new parts and drives genomic complexity

open access: yesFEBS Letters, EarlyView.
How do genomes gain new functional parts? In eukaryotes, which tend to evolve under weak selection, much of the genome is junk. Palazzo and Qiu borrow the logic of Markov chains to show how non‐functional DNA becomes functional through the appearance of intermediate states, which arise due to epistasis, buffering, and biochemical messiness, allowing ...
Alexander F. Palazzo, Yi Qiu
wiley   +1 more source

Home - About - Disclaimer - Privacy