Results 191 to 200 of about 20,275,220 (250)

High-Resistance Grounding Fault Detector by Use of Feeding Current

open access: yesQuarterly Report of RTRI (Railway Technical Research Institute) (Japan), 2008
The detection of high-resistance grounding faults in DC electric railways is difficult due to the impossibility of distinguishing fault current from load current in such systems. We therefore propose a new detection method to distinguish fault current from load current using the total feeding current of two substations. The technique takes advantage of
Masataka Akagi
exaly   +3 more sources

Study on the Influence of Grounding Resistance on Cable Fault Overvoltage

open access: yesEnergies
The cable grounding connecting method and grounding resistance have a significant influence on the cable fault overvoltage. This paper considers a 500 kV long cable project in Beijing as the research object; a model was implemented in ATP-EMTP, and ...
Xiaoyue Chen
exaly   +2 more sources
Some of the next articles are maybe not open access.

Related searches:

Directional ground fault indicator for high-resistance grounded systems

IEEE Technical Conference Industrial and Commerical Power Systems, 2002
Locating ground faults is a difficult and challenging problem for low-voltage power systems that are ungrounded or have high-impedance grounding. Recent work in pilot signals has renewed efforts in developing fault location methodologies. This paper presents a method for directional ground-fault indication that utilizes the fundamental frequency ...
T. Baldwin, F. Renovich, L.F. Saunders
openaire   +1 more source

High-resistance neutral grounding in industrial systems and the ground fault protection

2013 Brazilian Power Electronics Conference, 2013
The objective of this paper is to present the state-of-the art in the high-resistance neutral grounding practice in LV (480V) and MV (4.16kV) industrial power systems, not still widely known in Brazil, especially regarding the ground fault detection and location systems, and equipment protection with selectivity.
Gladston A. F. Bernardi   +1 more
openaire   +1 more source

Fault Current Constrained Impedance-Based Method for High Resistance Ground Fault Location in Distribution Grid

Electric Power Systems Research, 2022
Fault locating technology is crucial to the safe operation of a distribution grid. Impedance-based method is quite promising in fault locating due to its low cost and easy implementation. However, this method suffers from low precision when locating high resistance ground fault.
Wei-Jian Yang   +3 more
openaire   +1 more source

Method to detect line-to-ground faults in high-resistance-ground networks

2010 IEEE Energy Conversion Congress and Exposition, 2010
An Industrial-Power-Converter-System (IPCS) is a system made up of several power converters, such as Adjustable Speed Drive (ASDs), filters, and any kind of reactive power-compensation components. Today, an IPCS requires the ability to accurately detect and isolate electric faults to avoid further compromise of the integrity of the whole system.
Carlos D. Rodriguez-Valdez   +1 more
openaire   +1 more source

Fault locating in ungrounded and high-resistance grounded systems

IEEE Transactions on Industry Applications, 2001
One of the most common and difficult problems to solve in industrial power systems is the location and elimination of the ground fault. Ground faults that occur in ungrounded and high-resistance grounded systems do not draw enough current to trigger circuit breaker or fuse operation, making them difficult to localize. Techniques currently used to track
T. Baldwin   +3 more
openaire   +1 more source

High-Resistance Grounding of 2400-Volt Delta Systems with Ground-Fault Alarm and Traceable Signal to Fault

IEEE Transactions on Industry and General Applications, 1965
A method is described which has been used to reduce the difficulties encountered on several old delta-ungrounded systems. Data are included which will help in applying this to any particular power system. The scheme gives an alarm whenever a ground fault occurs, permits everything to keep running even more assuredly than with an ungrounded system, and ...
Francis K. Fox   +2 more
openaire   +1 more source

High-Resistance Grounding and Selective Ground Fault Protection for a Major Industrial Facility

IEEE Transactions on Industry Applications, 1984
The high-resistance grounded system offers the distinct advantage of service continuity under single ground fault conditions which is critical to many industries such as petroleum, chemical, mining, textile, cement, pulp and paper, food, glass, utility, etc.
Gary N. Wang   +3 more
openaire   +1 more source

Ground fault location identification for multiple drive high resistance grounding systems

2013 IEEE Energy Conversion Congress and Exposition, 2013
One of the more difficult problems to solve in industrial plants is to locate and eliminate a ground fault in High Resistance Grounding (HRG) system. This is because ground fault conditions in these systems do not draw enough current to reliably trip the ground fault current detector in the drive. This paper studied the ground fault identification (GFI)
Lixiang Wei   +3 more
openaire   +1 more source