Results 11 to 20 of about 154,492 (354)
High voltage circuit-breakers with superior performance are demanded as the transmission distance extends and voltage rises, which are often subject to high current and voltage surges.
Yi Ding +9 more
semanticscholar +1 more source
An essential piece of equipment for the protection and management of the electricity grid is a high voltage(HV) circuit breaker. The reliability and stability of the electricity grid are directly affected by the condition of operation of a high voltage ...
Kuan Zhang +3 more
doaj +1 more source
Parameters design of voltage sharing components for the series multi‐break mechanical switch
Series multi‐break mechanical switch is one of the critical components of high‐voltage hybrid DC circuit breakers. However, due to the existence of distributed capacitance, the voltage distribution between the breaks is not balanced.
Daochun Huang +5 more
doaj +1 more source
This paper presents a design and performance evaluation of three different overvoltage suppression circuits employed in a solid-state circuit breaker for medium- to high-power and low- to medium-voltage DC grids.
Andreas Giannakis, Dimosthenis Peftitsis
doaj +1 more source
Real-Time Monitoring of High Voltage Switch Based on CAD
In the process of online real-time monitoring of intelligent digital filter high-voltage switchgear, the mechanical state diagnosis of high-voltage circuit breaker is based on fully understanding the mechanical characteristics of each component of ...
Long Di +5 more
doaj +1 more source
The direct current (DC) circuit breaker based on semiconductor power devices is one of the critical components in multiterminal flexible high voltage DC transmission technology.
Xin Liu +3 more
doaj +1 more source
High Voltage Circuit Breaker Vibration Signature Indices Evaluation for Condition Assessment
The importance of the high voltage circuit breaker for the power system’s safe and reliable operation is paramount. This research aims to analyse and provide the most significant high voltage circuit breaker health state indices based on the non-invasive
Kerim Obarcanin +2 more
semanticscholar +1 more source
New two chamber transfer switch for 6500 A commutation current
HVDC transfer switches are used in different locations in electrode lines of HVDC transmission systems for their reconfigurations. They have to carry and commutate currents to the overload currents of HVDC transmission systems, which increased to 6,400A ...
Lutz-Rüdiger Jänicke +4 more
doaj +1 more source
When the direct current circuit breaker (DCCB) fails to operate, the fault range will further expand, endangering the safe operation of the power gird.
Andi Li +4 more
doaj +1 more source
Influence of grid configuration on current conducting behaviour in PV installations [PDF]
On the roof of an industrial site a 385 kWp PhotoVoltaic installation is operational. When production of this system reaches 60% of the installed power, the circuit breaker trips.
Debruyne, Colin +3 more
core +2 more sources