Results 31 to 40 of about 154,492 (354)
Topology assessment for 3 + 3 terminal offshore DC grid considering DC fault management [PDF]
Peer ...
Jovcic, Dragan +3 more
core +1 more source
Experimental Test bed to De-Risk the Navy Advanced Development Model [PDF]
This paper presents a reduced scale demonstration test-bed at the University of Texas’ Center for Electromechanics (UT-CEM) which is well equipped to support the development and assessment of the anticipated Navy Advanced Development Model (ADM).
Feng, X +6 more
core +1 more source
Graphene-Enhanced CuW Composites for High-Voltage Circuit Breaker Electrical Contacts
To address the issue of over-standard short-circuit currents in a power system, it is imperative to enhance the comprehensive performance of the electrical contacts, which serve as the lynchpin of circuit breakers, so as to improve the breaking capacity ...
Tan Liu +6 more
semanticscholar +1 more source
Basic contents of on-line monitoring technologies of mechanical characteristics of high-voltage vacuum circuit breaker were introduced, and various kinds of methods of on-line monitoring were reviewed.
ZHAO Yang
doaj +1 more source
In recent years, machine learning techniques have been applied to test the fault type in high-voltage circuit breakers (HVCBs). Most related research involves in improving the classification method for higher precision. Nevertheless, as an important part
Suliang Ma +5 more
semanticscholar +1 more source
Mechanism Analysis and Simulation Study of Closing Overvoltage Fault in EMU Circuit Breaker
Objective The overvoltage caused by circuit breaker closing will aggravate the insulation aging of high voltage equipment when EMU (electric multiple units)passes neutral section.
ZHANG Mingrui +2 more
doaj +1 more source
Experimental Modeling of Forward Recovery Characteristics of IGBT for DC Circuit Breaker
DC circuit breaker is the main means to clear the faults in VSC-HVDC power grid. Before action of the hybrid DC circuit breaker, the IGBT in the transfer branch is in a state of zero voltage and zero current.
Hong SHEN +4 more
doaj +1 more source
Optimizing the roles of unit and non-unit protection methods within DC microgrids [PDF]
The characteristic behavior of physically compact, multiterminal dc networks under electrical fault conditions can produce demanding protection requirements.
Burt, Graeme +4 more
core +1 more source
With the development of a distributed generation, direct current (DC) load and energy‐storage equipment, voltage‐source‐converter‐based medium‐voltage DC systems (VSC‐MVDC) have attracted more attention due to its low power consumption, high reliability,
Muhammad Junaid +6 more
doaj +1 more source
Analysis of SF6 contact based on QPSO-SVR
In the condition evaluation of the high-voltage SF6 circuit breaker, contact resistance and mass loss have a significant impact on the arc contact. To that end, this paper proposes a method based on quantum particle swarm optimization and support vector ...
Jianwei Bai +6 more
doaj +1 more source