Discussion of Doubly-Fed Wind Turbines Technical Solutions on High Voltage Ride-Through

Advanced Materials Research, 2014
Aiming at the problem appears in recent years, which is caused by the grid voltage swell, this paper analyzed the reasons for the voltage swell and its harm of the voltage swell to doubly-fed wind turbine. According to the derivation of doubly-fed wind turbine’s transient process when voltage swells, the paper proposed several technical solutions of ...
Jing Chang   +3 more
openaire   +1 more source

High performance AC–DC control power supply for low voltage ride through inverters

Sadhana, 2016
This paper presents a control power supply (CPS) design which is used to feed power to the subsystems of a power converter. The CPS design presented here maintains a constant 24V dc output even over a wide (90V rms to 270V rms ) ac voltage variation ...
K SAICHAND, AKSHAY KUMRAWAT, VINOD JOHN
openaire   +1 more source

Research on Precise Voltage Regulation Control Strategy of High and Low Voltage Ride Through Test Device of Inverter

2021 6th Asia Conference on Power and Electrical Engineering (ACPEE), 2021
In order to improve the accuracy of high and low voltage ride through test of low voltage auxiliary inverter and effectively solve the problems of large test voltage error and long voltage conversion time, on the basis of the existing test equipment, a more perfect precision control strategy was proposed.
Tao Qiu   +3 more
openaire   +1 more source

Low voltage ride through control strategy for high-power grid-connected photovoltaic inverter

2013 Twenty-Eighth Annual IEEE Applied Power Electronics Conference and Exposition (APEC), 2013
This paper presents a low voltage ride through (LVRT) control strategy for high-power grid-connected photovoltaic (PV) inverter, which can assure the PV inverter operates under grid faults with sinusoidal output currents. The control strategy of PV inverter is made up of inner current loops and outer voltage loop in a cascade structure under normal ...
Xianwen Bao   +3 more
openaire   +1 more source

Hybrid high-power rectifier with reduced THDI and voltage sag ride-through capability

2011 IEEE Industry Applications Society Annual Meeting, 2011
Temporary voltage sags are the main cause of untimely arrest in automated systems that use adjustable speed drives (ASDs). In this context, this paper presents an analysis of a new hybrid three-phase rectifier designed to correct the power factor and to promote voltage sag ride-through capability to ASDs.
Admarco V. Costa   +5 more
openaire   +1 more source

A coordinated control strategy of DFIG-based WECS for high voltage ride-through enhancement

2014 17th International Conference on Electrical Machines and Systems (ICEMS), 2014
This paper presents an analysis and operation of a Doubly Fed Induction Generator (DFIG)-based wind energy conversion system (WECS) under voltage swell condition. By taking into account both converters' current ratings, a coordinated control scheme of the Grid Side Converter (GSC) and Rotor Side Converter (RSC), with dynamic reactive power supporting ...
Yang Fang, Dan Sun, Pinghua Xiong
openaire   +1 more source

IMC robust control for high‐voltage ride‐through of doubly fed induction wind generator

IEEJ Transactions on Electrical and Electronic Engineering, 2018
To solve system parameter variation such as magnetic circuit saturation and excitation inductance of the doubly fed induction generator (DFIG) caused by grid voltage swells, a high‐voltage ride‐through (HVRT) robust control method for the DFIG based on the internal model control (IMC) controller is proposed.
Xiaoyang Ma, Honggeng Yang
openaire   +1 more source

High voltage ride-through control strategy of grid-side converter for DFIG-based WECS

IECON 2013 - 39th Annual Conference of the IEEE Industrial Electronics Society, 2013
For doubly-fed induction generator (DFIG)-based wind energy conversion system (WECS), grid voltage swell is harmful to the dc-link capacitor and the grid-side converter (GSC). The grid over-voltage may lead to the reversal of power flow in the GSC, resulting in the uncontrollability of the GSC. In order to handle this situation, the control strategy of
Zhong Zheng, Geng Yang, Hua Geng
openaire   +1 more source

Test System Design of Low Voltage Ride Through of High Altitude Photovoltaic Power Station

2018 China International Conference on Electricity Distribution (CICED), 2018
the photovoltaic resources are abundant in the high altitude area of northwest China, but the network frame is weak in this kind of area, and it is urgent to carry out the detection of Photovoltaic grid connected network test. It is necessary to solve the problem of system insulation safety with Low Voltage Ride Through (LVRT) test for photovoltaic ...
Wang Deshun   +4 more
openaire   +1 more source

Application of SMES unit to improve the high-voltage-ride-through capability of DFIG-grid connected during voltage swell

2011 IEEE PES Innovative Smart Grid Technologies, 2011
The amount of wind turbine connected to the power grid has significantly increased during the last decade. This has resulted in essential need to establish grid codes. Previously, wind turbine generators (WTGs) were allowed to be disconnected from the network during any disturbance at the grid side to avoid WTGs from being damaged. However, lately, the
A. M. Shiddiq Yunus   +2 more
openaire   +1 more source