Implementation of an Open-Source Multiplexing Ion Gate Control for High Kinetic Energy Ion Mobility Spectrometry (HiKE-IMS) [PDF]
With ion mobility spectrometry increasingly used in mass spectrometry to enhance separation by increasing orthogonality, low ion throughput is a challenge for the drift-tube ion mobility experiment. The High Kinetic Energy Ion Mobility Spectrometer (HiKE-IMS) is no exception and routinely uses duty cycles of less than 0.1%. Multiplexing techniques such
Stefan Zimmermann +2 more
exaly +11 more sources
Positive Reactant Ion Formation in High Kinetic Energy Ion Mobility Spectrometry (HiKE-IMS) [PDF]
In contrast to classical Ion Mobility Spectrometers (IMS) operating at ambient pressure, the High Kinetic Energy Ion Mobility Spectrometer (HiKE-IMS) is operated at reduced pressures of between 10 and 40 mbar and higher reduced electric field strengths of up to 120 Td.
Ansgar T Kirk +2 more
exaly +6 more sources
Negative Reactant Ion Formation in High Kinetic Energy Ion Mobility Spectrometry (HiKE-IMS) [PDF]
Due to the operation at background pressures between 10-40 mbar and high reduced electric field strengths of up to 120 Td, the ion–molecule reactions in High Kinetic Energy Ion Mobility Spectrometers (HiKE-IMS) differ from those in classical ambient pressure IMS.
Ansgar T Kirk +2 more
exaly +6 more sources
High Kinetic Energy Ion Mobility Spectrometry (HiKE-IMS) at 40 mbar [PDF]
High Kinetic Energy Ion Mobility Spectrometers (HiKE-IMS) are usually operated at an absolute pressure of 20 mbar reaching high reduced electric field strengths of up to 125 Td for controlled reaction kinetics. This significantly increases the linear range and limits chemical cross sensitivities.
Ansgar T Kirk +2 more
exaly +6 more sources
The origin of isomerization of aniline revealed by high kinetic energy ion mobility spectrometry (HiKE-IMS) [PDF]
Three ion mobility peaks of 4-fluoroaniline, including the para-protonated and molecular ion species, when measured with a high-kinetic energy ion mobility spectrometer and peak abundances depend only on the ionization settings.
Ansgar T Kirk +2 more
exaly +5 more sources
Field-Dependent Reduced Ion Mobilities of Positive and Negative Ions in Air and Nitrogen in High Kinetic Energy Ion Mobility Spectrometry (HiKE-IMS) [PDF]
In High Kinetic Energy Ion Mobility Spectrometry (HiKE-IMS), ions are formed in a reaction region and separated in a drift region, which is similar to classical drift tube ion mobility spectrometers (IMS) operated at ambient pressure. However, in contrast to the latter, the HiKE-IMS is operated at a decreased background pressure of 10–40 mbar and ...
Ansgar T Kirk +2 more
exaly +6 more sources
Ion Mobility Shift of Isotopologues in a High Kinetic Energy Ion Mobility Spectrometer (HiKE-IMS) at Elevated Effective Temperatures [PDF]
Ion mobility spectrometers (IMS) separate ions mainly by ion–neutral collision cross section and to a lesser extent by ion mass and effective temperature. When investigating isotopologues, the difference in collision cross section can be assumed negligible.
Ansgar T Kirk +2 more
exaly +6 more sources
Here, we present proof of principle studies to demonstrate how the product ions associated with the ion mobility peaks obtained from a High Kinetic Energy-Ion Mobility Spectrometer (HiKE-IMS) measurement of a volatile can be identified using a Proton ...
Stefan Zimmermann +2 more
exaly +3 more sources
Therapeutic nano‐drug delivery systems interact with cellular mitochondria in a multitude of ways. While the complexity of such interactions disrupts the mitochondrial electron transport chain and increases reactive oxygen species production, thereby contributing to nanoparticle toxicity, they also present unique theranostic opportunities in diseases ...
Sourav Bhattacharjee
wiley +1 more source
Ising machines are emerging as specialized hardware solvers for computationally hard optimization problems. This review examines five major platforms—digital CMOS, analog CMOS, emerging devices, coherent optics, and quantum systems—highlighting physics‐rooted advantages and shared bottlenecks in scalability and connectivity.