Results 101 to 110 of about 72,597 (115)
Some of the next articles are maybe not open access.
Journal of the American Society for Mass Spectrometry, 2020
In contrast to classical ion mobility spectrometers (IMS) operating at ambient pressure, the high kinetic energy ion mobility spectrometer (HiKE-IMS) is operated at reduced pressures between 10-40 mbar. In HiKE-IMS, ions are generated in a reaction region before they are separated in a drift region.
Ansgar T Kirk +2 more
exaly +3 more sources
In contrast to classical ion mobility spectrometers (IMS) operating at ambient pressure, the high kinetic energy ion mobility spectrometer (HiKE-IMS) is operated at reduced pressures between 10-40 mbar. In HiKE-IMS, ions are generated in a reaction region before they are separated in a drift region.
Ansgar T Kirk +2 more
exaly +3 more sources
Journal of the American Society for Mass Spectrometry, 2021
Classical ion mobility spectrometers (IMS) operated at ambient pressure, often use atmospheric pressure chemical ionization (APCI) sources to ionize organic compounds. In APCI, reactant ions ionize neutral analyte molecules via gas-phase ion–molecule reactions. The positively charged reactant ions in purified, dry air are H3O+, NO+, and O2+•.
Ansgar T Kirk +2 more
exaly +3 more sources
Classical ion mobility spectrometers (IMS) operated at ambient pressure, often use atmospheric pressure chemical ionization (APCI) sources to ionize organic compounds. In APCI, reactant ions ionize neutral analyte molecules via gas-phase ion–molecule reactions. The positively charged reactant ions in purified, dry air are H3O+, NO+, and O2+•.
Ansgar T Kirk +2 more
exaly +3 more sources
Journal of the American Society for Mass Spectrometry, 2022
High Kinetic Energy Ion Mobility Spectrometers (HiKE-IMS) chemically ionize gaseous samples via reactant ions and separate the generated ions by their motion in a neutral gas under the influence of an electric field. Operation at reduced pressures of 10–40 mbar allows for reaching high reduced electric field strengths (E/N) of up to 120 Td.
Ansgar T Kirk +2 more
exaly +3 more sources
High Kinetic Energy Ion Mobility Spectrometers (HiKE-IMS) chemically ionize gaseous samples via reactant ions and separate the generated ions by their motion in a neutral gas under the influence of an electric field. Operation at reduced pressures of 10–40 mbar allows for reaching high reduced electric field strengths (E/N) of up to 120 Td.
Ansgar T Kirk +2 more
exaly +3 more sources
Recent progress in food flavor analysis using gas chromatography–ion mobility spectrometry (GC–IMS)
Food Chemistry, 2020Hai-Tao Chen, Shuqi Wang
exaly
The Time-Varying Impact of the Federal Reserve Rate Hike on Bitcoin
Applied Economics and Policy Studies, 2023exaly
Validity and relevance of the pack hike wildland firefighter work capacity test: a review
Ergonomics, 2010Warren Payne +2 more
exaly