Results 221 to 230 of about 61,398 (342)

Flexible Chemiresistive Chitosan‐Glycerol Sensors on Laser‐Induced Graphene Electrodes for Room‐Temperature Ammonia Detection

open access: yesAdvanced Materials Technologies, EarlyView.
Flexible Chitosan‐glycerol sensor integrated with porous laser‐induced graphene (LIG) electrodes enable room‐temperature chemiresistive detection of ammonia (NH3) and proof‐of‐concept detection of fish spoilage. ABSTRACT We report a metal‐free sensor platform combining laser induced graphene (LIG) electrodes with drop‐deposited, glycerol‐plasticized ...
Mintesinot Tamiru Mengistu   +9 more
wiley   +1 more source

Chemically Doped Conductive Polymers for Wearable Health Monitoring

open access: yesAdvanced Materials Technologies, EarlyView.
Among conductive polymers, poly(3,4‐ethylenedioxythiophene):poly(styrenesulfonate) (PEDOT:PSS), polyaniline (PANI), and polypyrrole (PPy) are the most studied and applied. Chemical doping significantly boosts intrinsic conductivity and mechanical robustness.
Mengdi Zuo   +5 more
wiley   +1 more source

Uncovering persistent biases in human path integration by separating left and right trials. [PDF]

open access: yesSci Rep
Scherer J   +5 more
europepmc   +1 more source

Smart Closed‐Loop Systems in Personalized Healthcare: Advances and Outlook

open access: yesAdvanced Materials Technologies, EarlyView.
A smart closed‐loop e‐textile integrates multimodal sensing, onboard processing, wireless communication, and wearable power to enable real‐time physiological/biochemical monitoring and feedback‐controlled therapy. ABSTRACT Smart textiles represent a revolutionary frontier in healthcare, seamlessly blending fabric and advanced technologies to create ...
Safoora Khosravi   +12 more
wiley   +1 more source

Grid cells accurately track movement during path integration-based navigation despite switching reference frames. [PDF]

open access: yesNat Neurosci
Peng JJ   +6 more
europepmc   +1 more source

Fabric‐Based Wearable Robotic Exoskeleton Gloves: Advancements and Challenges

open access: yesAdvanced Materials Technologies, EarlyView.
This review highlights interdisciplinary technological advances in fabric‐based robotic gloves, focusing on progress in design, fabrication, actuation, sensing, control, and power and energy requirements. It also addresses performance testing and validation, including biomechanical, strength, functional, user experience, and durability assessments, to ...
Ayse Feyza Yilmaz   +2 more
wiley   +1 more source

Cap‐oPMN: Oral Inflammatory Load Quantification Using Capillary Microfluidics and Automated Image Processing

open access: yesAdvanced Materials Technologies, EarlyView.
ABSTRACT Quantifying oral polymorphonuclear neutrophils (oPMNs) is a clinically validated approach for assessing periodontal inflammation. However, current methods, such as manual hemocytometry and flow cytometry, are time‐consuming (>3 h), require invasive sampling, and depend on staining and complex instrumentation, making them unsuitable for point ...
Mohsen Hassani   +9 more
wiley   +1 more source

Home - About - Disclaimer - Privacy