Results 31 to 40 of about 37,617 (247)

Long-range distributed optical fiber hot-wire anemometer based on chirped-pulse ΦOTDR.

open access: yesOptics Express, 2018
We demonstrate a technique allowing to develop a fully distributed optical fiber hot-wire anemometer capable of reaching a wind speed uncertainty of ≈ ±0.15m/s (±0.54km/h) at only 60 mW/m of dissipated power in the sensing fiber, and within only four ...
A. Garcia-Ruiz   +5 more
semanticscholar   +1 more source

High-sensitivity hot-wire anemometer using cobalt-doped fiber-based long-period gratings.

open access: yesOptics Express
A high-sensitivity hot-wire anemometer is proposed for use with a cobalt-doped fiber (CDF) based long-period grating (LPG) heated optically by a 1480 nm laser.
Langzhe Du   +7 more
semanticscholar   +1 more source

Wind Energy and the Turbulent Nature of the Atmospheric Boundary Layer [PDF]

open access: yes, 2012
Wind turbines operate in the atmospheric boundary layer, where they are exposed to the turbulent atmospheric flows. As the response time of wind turbine is typically in the range of seconds, they are affected by the small scale intermittent properties of
Allan Morales   +25 more
core   +1 more source

Determination of Wall Friction Velocity of the Turbulent Boundary Layer by Two-Parameter Nonlinear Curve Fitting

open access: yesXibei Gongye Daxue Xuebao, 2020
Hot-wire anemometer is a fundamental tool for flow field measurement, and has been widely adopted in research of turbulent flow. A turbulent boundary layer was generated by a trip wire and a piece of sandpaper in the low-speed wind tunnel, and the time ...

doaj   +1 more source

Excitation of localized wave packet in swept-wing supersonic boundary layer

open access: yesMATEC Web of Conferences, 2017
The evolution of the artificial wave packet in swept-wing supersonic boundary layer was experimentally studied at M = 2. The localized disturbances were generated by a pulse glow discharge. Measurements were provided by a hot-wire anemometer. The spatial
Yatskikh Aleksey   +4 more
doaj   +1 more source

Detailed airflow dynamics and temperature data of axisymmetric and anisothermal jets developing in a room

open access: yesData in Brief, 2020
HVAC systems are often used to reach thermal comfort in buildings. It is then necessary to understand the resulting indoor airflow and thermal conditions to optimize the systems.
Teddy Gresse   +2 more
doaj   +1 more source

Response of the Shock Wave/Boundary Layer Interaction to Disturbances Induced by the Plasma Discharge

open access: yesAerospace, 2023
The paper focuses on the investigation of unsteady effects in shock wave/boundary layer interaction. The study was carried out using a flat plate model subjected to a free stream Mach number of 1.43 and a unit Reynolds number (Re1) of 11.5 × 106 1/m.
Oleg Vishnyakov   +2 more
doaj   +1 more source

Metallic hot wire anemometer [PDF]

open access: yes, 1977
A hot wire anemometer is described which has a body formed of heat resistant metal such as an alloy high in nickel content which supports a probe wire disposed in a V groove in the body.
Lemos, F. R.
core   +1 more source

Finalisation of the European Approach to Assess the Fire Performance of Facades—Brief Information on the Outcome of the Project

open access: yesFire and Materials, EarlyView.
ABSTRACT This research was conducted within the framework of project SI2.825082, funded by the European Commission—DG GROW. The project's objective was to finalise a European approach for assessing the fire performance of façades under medium and large fire exposure conditions.
Péter Tóth   +7 more
wiley   +1 more source

Oscillating hot-wire anemometer [PDF]

open access: yes, 1972
Performance analysis was made of oscillating hot-wire anemometer electrical output in gas stream.
Conley, J. M.
core   +1 more source

Home - About - Disclaimer - Privacy