Results 131 to 140 of about 65,219 (255)
This paper deals with the problem of trajectory tracking of a class of bilinear systems with time--varying measurable disturbance. A set of matrices {A,B_i} has been identified, via a linear matrix inequality, for which it is possible to ensure global ...
Bergna, G. +5 more
core +4 more sources
One of the main disadvantages of the multi-level solid-state transformer (SST) system is the voltage imbalance on the output of the rectifier modules.
Hyeok-Jin Yun +4 more
doaj +1 more source
A hybrid multilevel converter for medium and high voltage applications [PDF]
This paper investigates the suitability of the hybrid multilevel converter for medium and high voltage application. The converter operation, modulation, and capacitor voltage balancing method are described in detail.
Adam, Grain Philip +4 more
core
As the proportion of HVDC infeed power increases in the eastern receiving-end power grid, inertia and frequency regulation capability decrease. Utilizing modular multilevel converter (MMC) stations at the receiving-end to provide active frequency support
Baoye Tian +7 more
doaj +1 more source
With the increasing uncertainty introduced by the large-scale integration of renewable energy sources, traditional power dispatching methods face significant challenges, including severe frequency fluctuations, substantial forecasting deviations, and the
Min Cheng +5 more
doaj +1 more source
Stability analysis of electric power systems for ‘more electric’ aircraft [PDF]
This paper presents a comprehensive assessment of small-signal stability for a “more-electric” aircraft power system consisting of a synchronous variable-frequency generator which supplies several power electronic controlled loads via an 18-pulse ...
Griffo, Antonio, Howe, D., Wang, J.B.
core
Bài báo nghiên cứu lựa chọn các giải pháp đấu nối nhà máy điện gió ngoài khơi vào hệ thống điện Việt Nam, với hai giải pháp đấu nối hiện nay là truyền tải điện xoay chiều (HVAC) và truyền tải điện một chiều (HVDC).
Le Hong Lam +3 more
doaj
In the context of extensive integration of renewable energy sources into the electrical grid, the grid's fault transient behaviors have undergone significant changes.
Yuanhong Lu +6 more
doaj +1 more source
HAPF (high voltage active power filter) and SVG (static var generator), which are specially used for filtering in large-capacity HVDC projects, are configured in the Min-Yue back-to-back HVDC transmission project to meet the filtering requirements and ...
Xiao LEI +4 more
doaj +1 more source
Integration of renewable resources such as remote solar or wind farms and electricpower trading between neighbouring countries lead to new requirements on the development of thetransmission grids. Since AC grid expansion is limited by e.g.
Fidai, Muhammad Hassan
core +1 more source