Results 81 to 90 of about 780,710 (181)

A Novel Topology of Hybrid HVDC Circuit Breaker for VSC-HVDC Application [PDF]

open access: yesEnergies, 2017
The use of high voltage direct current (HVDC) circuit breakers (CBs) with the capabilities of bidirectional fault interruption, reclosing, and rebreaking can improve the reliable and safe operation of HVDC grids. Although several topologies of CBs have been proposed to perform these capabilities, the limitation of these topologies is either high on ...
Van-Vinh Nguyen   +4 more
openaire   +2 more sources

Analysis of Out‐of‐Step Oscillation Centre Migration Under Increasing Renewable Energy Penetration in Large‐Scale Power Systems

open access: yesIET Smart Energy Systems, Volume 2, Issue 3, Page 181-190, September 2026.
Increasing renewable penetration causes out‐of‐step oscillation centres to migrate away from renewable integration points. Two distinct migration modes—continuous drift and large‐range jumps with instability‐mode changes—are identified, providing guidance for adaptive splitting protection in future power systems.
Changsheng Chen   +8 more
wiley   +1 more source

A hybrid multi-port HVDC circuit breaker that improves interruption and reset time through shared energy dissipation and fault current regeneration

open access: yesResults in Engineering
This paper proposes a Hybrid Multi-Port DC Circuit Breaker (HMPDCCB) design that addresses the limitations of existing hybrid DC circuit breakers (HDCCBs), such as high cost, complexity, and slow response to high fault current and voltage demands.
Qumrish Arooj, Imtiaz Ahmad Taj
doaj   +1 more source

A Review of Overcurrent Protection in Smart Grids Under Cyber‐Physical Threats With a Cyber‐Physical Evaluation Framework

open access: yesEnergy Science &Engineering, Volume 14, Issue 8, Page 3948-3973, August 2026.
By manipulating current and voltage measurements, an assailant can induce unwanted relay action while attempting to avoid detection. Detecting advanced cyber intrusions in power protection environments requires specialised data analysis and anomaly detection methods.
Feras Alasali   +6 more
wiley   +1 more source

Investigations on the safe stroke of mechanical HVDC vacuum circuit breaker

open access: yesThe Journal of Engineering, 2019
Here, a DC vacuum arc interruption test based on the hybrid high-speed actuator and the method of commutation is carried out in the synthetic loop system. The safe stroke is one of the basic breaking parameters.
Ning Xia   +5 more
doaj   +1 more source

Dynamic Behaviour of Bubbles in Oil Under Electrothermal Ageing

open access: yesHigh Voltage, Volume 11, Issue 4, Page 975-986, August 2026.
ABSTRACT During long‐term operation of converter transformers, the internal oil–pressboard insulation undergoes irreversible degradation. Partial discharge in the weakened insulation will cause the formation of a large number of bubbles in the insulating oil.
Hongbin Wu   +7 more
wiley   +1 more source

HVDC Circuit Breaker Development and Applications in VSC-HVDC Transmission Project

open access: yesIOP Conference Series: Earth and Environmental Science, 2020
Abstract High voltage direct current (HVDC), especially voltage source based HVDC (VSC-HVDC), transmission technology has been expanding in recent decades. HVDC circuit breaker therefore attracts significant interest due to its abilities of current interruption and fault isolation.
Yuefeng Yang   +5 more
openaire   +1 more source

About the Ageing‐Induced Modifications of Physical‐Chemical and Electrical Properties of Polyimide (PMDA‐ODA) Under Gamma Radiation and High Temperatures

open access: yesHigh Voltage, Volume 11, Issue 4, Page 939-952, August 2026.
ABSTRACT This study investigates the effects of radiation‐induced ageing on the physical, chemical, mechanical and electrical properties of Poly[4,4′‐oxydiphenylene‐ pyromellitimide] (PMDA‐ODA) polyimide, a high‐performance insulation material widely used in aerospace applications.
Simone Vincenzo Suraci   +3 more
wiley   +1 more source

Improving interruption performance of mechanical circuit breakers by controlling pre-current-zero wave shape

open access: yesHigh Voltage, 2019
Mechanical circuit breakers (MCBs) are the limiting component for current injection HVDC circuit breakers. Improving their interruption performance reduces requirements for capacitance and inductance needed in the injection circuit and thus space use and
Tim Schultz   +5 more
doaj   +1 more source

A Novel Digital Twin Platform for Accelerating Power Systems Restoration

open access: yesEnergy Internet, Volume 3, Issue 2, Page 111-141, July 2026.
Hardware Architecture Design of DT System in Laboratory. ABSTRACT With the global energy structure transforming towards the goal of net zero emissions, the penetration of an inverter‐based resource (IBR) in power systems is increasing. This transformation poses two critical challenges: the system post blackout restoration process becomes extremely ...
Yiliang Fan   +8 more
wiley   +1 more source

Home - About - Disclaimer - Privacy