Results 21 to 30 of about 234 (147)
Research on a Novel DC Circuit Breaker Based on Artificial Current Zero-Crossing
Modular multilevel converter-based high voltage direct-current (MMC-HVDC) transmission has developed rapidly because of its flexibility, reliability and efficiency.
Shangfu Teng, Zhifeng Zhang, Liye Xiao
doaj +1 more source
Fault Interruption Scheme for HVDC System Using SiC-MESFET and VCB Based Hybrid Circuit Breaker
As high voltage DC power system is gaining popularity, power electronic switching devices are becoming increasingly advanced to overcome problems of timely fault isolation.
Waheed A. Khan +6 more
doaj +1 more source
A bipolar short‐circuit transient fault identification method for overhead transmission lines in modular multi‐level converter‐based high voltage direct current (MMC‐HVDC) grid based on the hybrid HVDC breaker is proposed.
Botong Li +5 more
doaj +1 more source
Current Limiting Hybrid High Voltage DC Circuit Breaker With Reclosing Function Limiting
DC circuit breaker is the core equipment for the safe operation of DC transmission system. A current limiting hybrid HVDC circuit breaker topology with reclosing function is proposed in this paper.
Baoge Zhang +4 more
doaj +1 more source
Controllable reactor based hybrid HVDC breaker
Short circuit fault occurrence in high-voltage DC (HVDC) systems causes extremely high currents in a fast raising time that does not experience current zero-crossing.
Amir Heidary +4 more
doaj +1 more source
Synthetic test circuit with two‐level voltage source for HVDC circuit breakers
In order to ensure the reliable interruption of high voltage direct current circuit breaker (HVDC CB), the breaking test of HVDC CB plays an important role in its performance verification.
Shixin Xiu +6 more
doaj +1 more source
Interruption limits of mechanical circuit breakers and circuit upgrades for current injection in HVDC circuit breakers [PDF]
Current injection circuit breakers consist of a mechanical interrupter (MI) with a current injection and an energy dissipation branch in parallel. The performance of the complete device is largely determined by mechanical operation time and interruption performance of the MI.
Tim Schultz +2 more
openaire +3 more sources
Key stress extraction and equivalent test method for hybrid DC circuit breaker
Firstly, relevant stress properties of millisecond level breaking process and microsecond level commutation process of hybrid HVDC circuit breaker are studied in detail on the basis of the analysis for the application environment and topological ...
Chong Gao +4 more
doaj +1 more source
Systematic Approach to HVDC Circuit Breaker Sizing [PDF]
High-voltage direct current (HVDC) grids can be protected by HVDC circuit breakers (DCCB) to selectively clear DC side faults and assure continuous operation of the healthy parts in the grid. Line inductors in series with DCCBs are essential to reduce the rate of rise of the fault current and to slow down the voltage decline in the healthy parts of the
Abedrabbo, Mudar +2 more
openaire +1 more source
Circuit Breaker Failure Protection Strategy for HVDC Grids
HVDC grids demand the fast and reliable operation of the protection system. The failure of any protection element should initialize a backup protection almost immediately in order to assure the system’s stability.
María José Pérez-Molina +3 more