Results 91 to 100 of about 780,710 (181)
An auto-reclosing scheme for DC circuit breaker in VSC-HVDC transmission system
When a DC line fault happens, the converter will be blocked instantly. This leads to an interruption of power transmission and influences the stability of DC and AC systems.
Yuan Wang +3 more
doaj +1 more source
Application of Deep Learning in Virtual Power Plants—A Review
ABSTRACT The advancement of deep learning (DL) has substantially improved the power grid’s ability to model and optimise diverse and highly complex tasks. Although intelligent transformation is an inevitable trend, traditional approaches increasingly reveal limitations in computational efficiency, nonlinear nonconvex optimisation, and multi‐layer ...
Hongjie Zhu +7 more
wiley +1 more source
Due to complex wind farm conditions, a coordinated control system was designed. It manages DC power surges during AC faults by temporarily storing excess energy and regulating voltages. This strategy optimizes unbalanced power and enables effective fault recovery, resulting in minimal voltage fluctuations and superior performance.
Lei Chen, Qi Han
wiley +1 more source
ABSTRACT The long‐term hydrophobic stability of silicone rubber (SiR) insulators is essential for their reliability in high‐voltage direct current (HVDC) applications. This study investigates the effect of nano‐silica fillers with varying specific surface areas (SSA = 120, 200 and 300 m2/g) and different concentrations of alumina trihydrate (ATH ...
Mahmoud A. Ali +3 more
wiley +1 more source
A Hybrid DC Circuit Breaker with Fault-Current-Limiting Capability for VSC-HVDC Transmission System
The direct current circuit breakers are considered a promising option to protect the transmission line against commonly appearing line-to-ground fault.
Muhammad Ahmad, Zhixin Wang
doaj +1 more source
Hardware-in-the-loop Implementation of a Hybrid Circuit Breaker Controller for MMC-based HVDC Systems [PDF]
This paper presents a hardware-in-the-loop (HiL) implementation of hybrid circuit breaker (HCB) controllers for the half-bridge modular multilevel converter (HB-MMC) based high-voltage direct current (HVDC) system protection.
Yang Lin +6 more
core +1 more source
Development in HVDC Circuit Breaker - A Review
The increasing adoption of High Voltage Direct Current (HVDC) systems for efficient long-distance power transmission and renewable energy integration necessitates advanced protection mechanisms to ensure system stability and reliability. Among these, HVDC circuit breakers play a pivotal role in interrupting fault currents and safeguarding HVDC networks.
openaire +1 more source
Superconducting circuit breaker concepts for the protection of HVDC systems
Publisher Copyright: © 2019 Institution of Engineering and Technology.All rights reserved.The reliable protection of DC grids is still a challenge, mainly because of the fast operation required for interrupting the high current faults that could severely
D.M. Larruskain +9 more
core +1 more source
Bridge-type fault current limiter and hybrid breaker for HVDC grids applications
© The Institution of Engineering and Technology 2020. The fast raising nature of DC fault currents and sensitivity of high-voltage DC (HVDC) power converters to DC faults is critical protection issues.
Rouzbehi, K +9 more
core +1 more source
Technical assessment of load commutation switch in hybrid HVDC breaker
The development of a large scale high voltage direct current (HVDC) power grid requires a reliable, fast and lowloss circuit breaker. The load commutation switch (LCS) is an essential part of ABB's 1200 MW hybrid HVDC breaker concept which builds up a ...
Jacobson, Björn +5 more
core +1 more source

